Fujitsu PRIMERGY RX300 S3 Operating Manual page 93

Hide thumbs Also See for PRIMERGY RX300 S3:
Table of Contents

Advertisement

Hot-plug Components
Ê Lift the green movable snap-fits not more than 1 mm, and take the PCI board
off.
Ê Mount the new PCI board into the pull out aid as described in the next
section.
Ê Insert the pre-assembled PCI board into the hot-plug PCI slot.
Ê Secure the assembly with the locking slide on the card guide (move it in the
direction of the server front side).
Ê Activate the board using the relevant software or by pressing the button (a).
The power indicator for the hot-plug PCI slot (see
flashes green. The slot is in the enable sequence.
Ê Wait until the power indicator lights constant. The slot is now powered on.
I
If the boards do not match, the new board will not be commissioned
(see
section "Hot-Plug PCI Power Indicator not Lighting after
Replacing the Board" on page
Ê Replace the housing cover (see
page
95).
RX300 S3
72).
section "Opening/Closing the Housing" on
Operating manual
Hot-plug PCI Boards
table 5 on page
56)
93