TECHNICAL DATA

X3 Power Source
Mains connection voltage
Mains connection cable
Rated power at max. current
Supply current (maximum)
Supply current (effective)
Idle power
Open circuit voltage
No-load voltage, U
0
Fuse
Output
Welding current and voltage range
Power factor at max current
Efficiency at max current
Operating temperature range
Storage temperature range
EMC class
Minimum short-circuit power SSC of supply network
Degree of protection
External dimensions
Weight
Power supply for auxiliary devices
Standards
The equipment complies with the requirements for the CE mark.
400 / 400 AU
3~, 50/60 Hz
380 – 440 V (–10 %...+10 %) 380 – 440 V (–10 %...+10 %)
H07RN-F
4 G4
60 % ED
17.6 kVA
100 % ED
12.5 kVA
I
27 A
1max
I
19 A
1eff
Pi
< 20 W
U
52 – 57 V
av
U
47 – 57 V
0
25 A
60 % ED
400 A / 34 V
100 % ED
310 A / 29 V
25 A/15 V – 400 A/38V
λ
0.88
η
89 %
–20...+40 °C
–40...+60 °C
A
4.7 MVA
IP23S
L x W x H
629 x 230 x 414 mm
32 kg
U
110 V/150 W
aux
IEC 60974-1
IEC 60974-10
18
© Kemppi Oy 2018
500
4 G4
24.5 kVA
17 kVA
37 A
29 A
< 20 W
57 – 62 V
51 – 62 V
35 A
500 A / 39.0 V
390 A / 33.5 V
25 A/15 V – 500 A/43 V
0.90
90 %
–20...+40 °C
–40...+60 °C
A
5.2 MVA
IP23S
629 x 230 x 414 mm
36 kg
110 V/150 W
IEC 60974-1
IEC 60974-10
X3 MIG Welder
1814