Error Message
AE03
CPU1_DIMM3 has been disabled. A memory error was detected.
AE04
CPU1_DIMM4 has been disabled. A memory error was detected.
AE05
CPU1_DIMM5 has been disabled. A memory error was detected.
AE06
CPU1_DIMM6 has been disabled. A memory error was detected.
AE07
CPU2_DIMM1 has been disabled. A memory error was detected.
CPU2_DIMM2 has been disabled. A memory error was detected.
AE08
CPU2_DIMM3 has been disabled. A memory error was detected.
AE09
AE0A
CPU2_DIMM4 has been disabled. A memory error was detected.
AE0B
CPU2_DIMM5 has been disabled. A memory error was detected.
AE0C
CPU2_DIMM6 has been disabled. A memory error was detected.
AE81
CPU1_DIMM1 with error is
enabled.
AE82
CPU1_DIMM2 with error is
enabled.
CPU1_DIMM3 with error is
AE83
enabled.
AE84
CPU1_DIMM4 with error is
enabled.
AE85
CPU1_DIMM5 with error is
enabled.
AE86
CPU1_DIMM6 with error is
enabled.
AE87
CPU2_DIMM1 with error is
enabled.
AE88
CPU2_DIMM2 with error is
enabled.
Cause
CPU1_DIMM3 has been
disabled.
CPU1_DIMM4 has been
disabled.
CPU1_DIMM5 has been
disabled.
CPU1_DIMM6 has been
disabled.
CPU2_DIMM1 has been
disabled.
CPU2_DIMM2 has been
disabled.
CPU2_DIMM3 has been
disabled.
CPU2_DIMM4 has been
disabled.
CPU2_DIMM5 has been
disabled.
CPU2_DIMM6 has been
disabled.
An error in CPU1_DIMM1 was
detected, but because all
memory is currently disabled,
this DIMM was forcibly enabled.
An error in CPU1_DIMM2 was
detected, but because all
memory is currently disabled,
this DIMM was forcibly enabled.
An error in CPU1_DIMM3 was
detected, but because all
memory is currently disabled,
this DIMM was forcibly enabled.
An error in CPU1_DIMM4 was
detected, but because all
memory is currently disabled,
this DIMM was forcibly enabled.
An error in CPU1_DIMM5 was
detected, but because all
memory is currently disabled,
this DIMM was forcibly enabled.
An error in CPU1_DIMM6 was
detected, but because all
memory is currently disabled,
this DIMM was forcibly enabled.
An error in CPU2_DIMM1
occurred, but because all
memory is currently disabled,
this DIMM was forcibly enabled.
An error in CPU2_DIMM2 was
detected, but because all
memory is currently disabled,
this DIMM was forcibly enabled.
Express5800/T120e Maintenance Guide
Solution
Contact your sales representative.