Lcd Display Icons - MPP Solar 3KW User Manual

Pip-mk series inverter / charger
Table of Contents

Advertisement

LCD Display Icons

Icon
Input Source Information
Configuration Program and Fault Information
Output Information
Battery Information
In AC mode, it will present battery charging status.
Status
Constant
Current mode /
Constant
Voltage mode
Floating mode. Batteries are fully charged.
In battery mode, it will present battery capacity.
Load Percentage
Load >50%
Load < 50%
Indicates the AC input.
Indicates the PV input
Indicate input voltage, input frequency, PV voltage, charger current,
charger power, battery voltage.
Indicates the setting programs.
Indicates the warning and fault codes.
Warning:
Fault:
Indicate output voltage, output frequency, load percent, load in VA,
load in Watt and discharging current.
Indicates battery level by 0-24%, 25-49%, 50-74% and 75-100% in
battery mode and charging status in line mode.
Battery voltage
<2V/cell
2 ~ 2.083V/cell
2.083 ~ 2.167V/cell
> 2.167 V/cell
Battery Voltage
< 1.85V/cell
1.85V/cell ~ 1.933V/cell
1.933V/cell ~ 2.017V/cell
> 2.017V/cell
< 1.892V/cell
Function description
flashing with warning code.
lighting with fault code
LCD Display
4 bars will flash in turns.
Bottom bar will be on and the other three
bars will flash in turns.
Bottom two bars will be on and the other two
bars will flash in turns.
Bottom three bars will be on and the top bar
will flash.
4 bars will be on.