2.4. Async bus connection

2.4.1. Timing chart

Async bus Write/Read timing
No.
1
H_CE setup time
2
H_WE/H_RE period
3
H_WE/H_RE high-level period
4
Data/Address setup time
5
H_CE hold time
6
Data/Address latch timing
7
Waiting time from other CE access to H_CE active
8
Waiting time from H_CE high-edge to CE access
Copyright © 2012-2014 Heartland. Data Inc.
Description
- 3 -
DT10 Hardware Manual
MIN.
MAX.
UNIT
0
ns
54
ns
27
ns
27
ns
0
ns
10
ns
0
ns
0
ns