Download Print this page
SOMFY LS40 404R2 Installation Instructions

SOMFY LS40 404R2 Installation Instructions

Ls40 series

Advertisement

Quick Links

Fig. 1
C
Motor End
B =A-(C+D)
For All Round Tubes
A
B
Fig. 2
Tube Notch
Notch: LS40
Length =
Fig. 3
Raised Key
Fig. 4
Raised Key
Fig. 5
Notch
Raised Key
Fig. 6
LS40 Motor
Installation Instructions
D
B
A
Idler End
A
B
in./mm
Width =
in./mm
.335 / 8.5
.236 / 6
Notch
R
1. TUBE PREPARATION
!
Cut the tube to the required length (B), taking into account
the width of the installation (A), the motor end clearance,
which includes motor head and motor bracket thickness
(C), and the idler end clearance, which includes idler end
cap and idler bracket thickness (D). (See Fig. 1)
!
USE FORMULA TO DETERMINE MEASUREMENTS.
!
Remove all burrs from the ends of the tube and ensure that
the inside of the tube is clean.
!
For all round tubes, notch the tube on the motor end to the
dimensions A & B. (See Fig. 2)
2. PREPARING THE TUBULAR MOTOR
!
Carefully pull open the one piece crown in order to fit over
the body of the motor. Slide the opening of the crown
wheel over the recessed part of the motor's limit switch unit
and close it over the Raised Key. (See Fig. 3)
!
Fit the drive wheel onto the output shaft of the motor.
3. FITTING THE MOTOR INTO THE TUBE
For round tubes: Measure the drilling length R according to
the motor type listed in the table below.
the tube ensuring that the notch at the end of the tube
slides over the raised key on the crown wheel.
5) Secure the drive wheel to the tube using four 5/32 steel
pop rivets or four #10 screws.
other side of the tube and secure it with three steel pop
rivets. Use only fasteners with steel grades SAE 5 or higher.
Metric fasteners must be grade 8.8 or higher. (See Fig. 6)
4. LIMIT SWITCH SETTING
SOMFY strongly recommends using a Tester Cable (T.C.) Cat.
No. 6020086 to set the motor limits, and to ensure the system
is operating correctly before the final electrical connection is
made. Refer to Step 6 "Trouble Shooting Guide" for any
problems encountered.
Two positions have to be set: the UP & DOWN positions,
this is where end product will stop automatically.
LS40
MOTOR
TYPE
401F1
404R2
404S2
409R2
412R2
Fit the motor into
(See Fig.4 &
Fit the end plug into the
UP POSITION
DOWN POSITION
R
in. / mm
16.6/421
16.6/421
16.6/421
16.6/421
16.6/421

Advertisement

loading

Summary of Contents for SOMFY LS40 404R2

  • Page 1 Metric fasteners must be grade 8.8 or higher. (See Fig. 6) Fig. 3 4. LIMIT SWITCH SETTING SOMFY strongly recommends using a Tester Cable (T.C.) Cat. Raised Key No. 6020086 to set the motor limits, and to ensure the system is operating correctly before the final electrical connection is made.
  • Page 2 - Check the wiring between the motor & the switch. output shaft. - Disconnect the switch & test the motor with a tester cable. SOMFY reserves the right to void the motor warranty if the wiring recommendations are not followed. SOMFY SYSTEMS, INC. SOMFY SYSTEMS, INC. reserves the SOMFY MEXICO S.A.

This manual is also suitable for: