User Menu 2 - Moretti Design AQUA User Manual

Hydro stove
Table of Contents

Advertisement

Press with a simple click the P3 button: the Display D2 starts flashing. By
pressing the button several times again, it is possible to change the
power setting according to the available values. Eg: 1-2-3-4-5-A (A =
Automatic Combustion). After 3 seconds the new set value is saved
and the display returns to its main screen.
Manual Pellet Loading
By pressing and holding the P3 button, the manual pellet loading
procedure is activated where the auger turns continuously. The bottom
display shows LoAd, the top one shows how much time the auger has
been turning. To stop the procedure, press any button. The loading
procedure stops automatically after 300 seconds.
Pellet Adjustment (models without FCS)
It is accessed by pressing and holding P2 button. The bottom display
shows PELL, the top shows the set value. With the P2/P4 buttons it is
possible to increase/decrease the value; the default value is 0. After 3
seconds the new value is saved and the display returns to its main screen.
Combustion Air Adjustment (models without FCS)
It is accessed by pressing and holding the P4 button. The bottom display
shows UEnt, the top one shows the set value. With the P2/P4 buttons, it
is possible to increase/ decrease the value; the default value is 0. After 3
seconds the new set value is saved and the display returns to its main
screen.

USER MENU 2

To access the menu, press and hold at the same time the P3 and P4
buttons for 3 seconds. With the P2/P4 buttons it is possible to select one
of the following items. Press P3 to access.
Cleaning Menu (CLn)
Menu that activates (On) or deactivates (OFF) the automatic burnerr
cleaning system (PLUS CLEAN models only).
Puffer Thermostat Menu (PuFF)
With this menu it is possible to change the value of the puffer thermostat
(visible only if configuration 2,3 or 4 is used). Press the P3 button to
enter edit mode. With the P2/P4 buttons it is possible to adjust the
temperature on the thermostat. To exit/go back, press the P1 button.
System Menu (tPAr)
It is possible to access the operating parameters of the stove. The
access is PASSWORD protected.
Learn Menu (LERr)
Learning menu code Display Radio (reserved for the authorized
technician).
MCS Menu (MCS) (models with FCS)
Menu for adjusting the automatic combustion correction range. Press the
P3 button to enter edit mode. With the P2/P4 buttons it is possible to
select a level. There are 10 steps, 5 that increase and 5 that decrease,
the 0 level is the manufacturers default setting. Press P3 to confirm. To
exit/go back press the P1 button.
Summer Winter Menu (FUnC)
Menu to select the operating mode: Summer (ESt) / Winter (InU)
Clock Menu (oroL)
Allows to set Time and Date. The top display shows hours and minutes,
the bottom display shows the day of the week. Press the P3 button to
enter edit mode. Modify the values with the P2/P4 buttons. Press the P3
button to enter edit mode of the parameters. Press again P3 to confirm
the set value. To exit/go back press the P1 button.
Remote Keyboard Menu (rEM)
Menu that activates (On) or deactivates (OFF) the Remote Keypad when
connected to the stove.
Chrono Menu (Cron)
This menu allows the setting the on/off switching time frames. There are
two options:
Modality (ModE)
Allows to enable the set program. Press the P3 button to enter edit
mode. With the P2/P4 buttons it is possible to select one of the following:
OFF (deactivate), Gior (Daily), SEtt (Weekly), FiSE (Week End). Press
the P3 button again to confirm the set value. To exit/go back press the
P1 button.
Chrono Program (PrOG)
Allows to select and program one of the following time frames.
Daily
Select Gior and press the P3 button to access. With the P2/P4 buttons it
is possible to select one of the programmed time frames.
15

Hide quick links:

Advertisement

Table of Contents
loading