Moretti Design ARIA User Manual

Air stove
Hide thumbs Also See for ARIA:

Advertisement

ARIA
USER MANUAL
AIR STOVE
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ARIA and is the answer not in the manual?

Questions and answers

Barbara
January 21, 2025

Can my Moretti 777 tower unit be used as a cold unit

1 comments:
Mr. Anderson
May 14, 2025

No, the Moretti ARIA tower unit is a pellet stove heater designed for heating. It is not intended for use as a cold unit.

This answer is automatically generated

Summary of Contents for Moretti Design ARIA

  • Page 1 ARIA USER MANUAL AIR STOVE...
  • Page 3: Table Of Contents

    INDEX INTRODUCTION Chrono General safety warnings Eco clima DESCRIPTION Calibration (models with FCS) Identification Calibration (models without FCS) Description of the stove Time and date INSTALLATION Load Supply conditions and unpacking Monitor Assembling Language Combustion air Settings Combustion air for a hermetic installation System menu Fume exhaust EMERGENCY CONTROL PANEL...
  • Page 4: Introduction

    On all Moretti Design products, at the end of the assembly line a manual. scrupulous check-up followed by a combustion test is carried out.
  • Page 5: Description Of The Stove

    The advanced software allows for the user a more simple and immediate comprehension of the heaters functions. The presence of a thermostat on all Moretti Design products allows the user to program the on/off switching function of the stove. The large pellet tank allows for a long period fuel loading procedure, avoiding this way that the user has to refill the tank too often.
  • Page 6 CHIMNEY FLUE INSIDE AN OLD CHIMNEY EXTERNAL CHIMNEY FLUE CORRECT CORRECT INSTALLATION INSTALLATION CHIMNEY WITH PROTECTION COVER PLATE INSULATION INSULATED CHIMNEY FLUE OPEN 45° CURVE CHIMNEY FLUE INSULATED “T” “T” WITH WITH INSPECTION INSPECTION CAP CHIMNEY FLUE WITHOUT “T” CHIMNEY FLUE THROUGH OUTSIDE WALL IMPROPER IMPROPER INSTALLATION...
  • Page 7: Operating Conditions

    While using the stove, the settings can not be changed or the protective casings removed. The control devices must be adjusted by Moretti Design qualified personnel. The maintenance of the product must be carried out by companies specialized in the maintenance of heating appliances and authorized by Moretti Design, which will submit it to all the checks ups required by the local regulations.
  • Page 8: Residual Risks

    FIRST IGNITION power supply. Caution: The first ignition must be carried out by MORETTI DESIGN SAFETY DEVICES qualified personnel that must also perform an overall check up of the system.
  • Page 9: Pellet Loading

    The antenna remains inside the stoves coating. Make sure that the white FCS (Fire Control System) tip of the antenna does not remain in contact with any metal parts of the It is an automatic combustion control system that stove, but it remains in contact with the glass or majolica coating. maintains the products high efficiency.
  • Page 10: Connection And Description On How A Ducted

    NON OPTIMAL combustion, the flame is too stretched and a large Optional amount of burning pellets are blown out of the burner. For a proper use of a ducted stove, it is appropriate that for each ducted • output a room sensor (model NTC 10k at 25°) or an ON/OFF thermostat Regulation on models with FCS: Reduce the MCS Calibration or a wireless thermostat is connected.
  • Page 11: Display Radio

    Button description DISPLAY RADIO Introduction Function Description Button The display radio (white) is a wireless device for the stove to which it is associated with and through it, it is possible Pressing the button when the main screen is to control and monitor the systems functions in real time. active, the device will continue to function Sleeping but will “fall asleep”...
  • Page 12: Normal

    Run Mode Room Thermostat After the ignition, the system goes into Run Mode. During this phase the This menu is used for setting the room thermostats used by the stove. heating fan is activated and the system operates on the set combustion •...
  • Page 13: Eco Clima

    • To select the item in the menu use the buttons. To The three different programs are memorized separately. eg: if the daily confirm press SET. To exit press ESC. program is modified, the other modalities do not change. Daily Eco Clima Select a desired day of the week and program the on/off switching time If the function is disabled, the stove goes into Modulation once the Room...
  • Page 14: Time And Date

    • Select hours, minutes and date with Auger Calibration Auger Calibration • Enter edit mode (flashing cursor) by pressing SET. Fan Calibration • Modify the selected value with and save the setting by Max: 5 pressing SET. Set: 0 • Press ESC to exit.
  • Page 15: System Menu

    Thermostat Management: The Menu allows to set the radio room thermostat function. Change Monitor Thermostat Manage Code Radio Standby Language Radio Test Monitor Thermostat Manage Thermostat Settings Managem Language Change Code 1000 Radio Standby System Menu 1001 Radio Test Settings Set Contrast 1002 Change Code...
  • Page 16: Emergency Control Panel

    Operating status shown EMERGENCY CONTROL PANEL Status Description CHEc Check up On 1, On 2, On 3, On 4 Ignition On 5 Stabilization Modulation StbY Standby Normal SAF/Erxx Safety Turn off Ignition recover Alt/Erxx Block Button description Other messages Click Press and hold Code Description...
  • Page 17: User Menu 2

    Press with a simple click the P3 button: the Display D2 starts flashing. By USER MENU 2 pressing the button several times again, it is possible to change the To access the menu, press and hold at the same time the P3 and P4 power setting according to the available values.
  • Page 18 In the Daily program it is possible to set 3 time frames for every single day of the week: Mo (monday), tU (tuesday), WE (wednesday), tH (thursday), Fr (friday), SA (saturday), Su (sunday). Make sure that in Modality (ModE) the item Gior (Daily) has been selected.
  • Page 19: Errors And Messages

    ERRORS AND MESSAGES Code Description Cause Operations to be performed Solutions Unblock and verify the proper If the fan is broken, contact an HEATING FAN BROKEN function of the fan authorised technician HIGH TEMPERATURE IN Unblock and turn on the stove, if PELLET TANK the error reoccurs turn off the stove Turn off due to...
  • Page 20 Code Description Cause Operations to be performed Solutions Turn off due to If the error persists, contact an Er15 BLACKOUT Power failure power failure authorised technician Turn off due to FLOWMETER INCORRECTLY If the error persists, contact an Er39 Unblock and turn on the stove flowmeter error CONNECTED OR BROKEN authorised technician...
  • Page 21: Control Unit - For A / Relax Models

    CONTROL UNIT - FOR A / RELAX MODELS LINE (230V 50Hz) Exhaust Fan Flowmeter Heating Fan (FCS) Auger Safety Thermostat Encoder Pressure Switch Exhaust Fume Probe Ignition Resistance Micro Emergency Control Panel Function Technical Features 230Vac +- 10% 50/60 Hz Main Power Supply F1= Fuse T 5,0 A Exhaust Fan...
  • Page 22: Control Unit - C (Single Hot Air Duct) / Models

    CONTROL UNIT - FOR C (SINGLE HOT AIR DUCT) MODELS LINE (230V 50Hz) Exhaust Fan Flowmeter Heating Fan (FCS) Heating Fan 2 Auger Micro Safety Thermostat Encoder Pressure Switch Exhaust Fume Probe Ignition Resistance Remote Room Thermostat Emergency Control Panel Function Technical Features 230Vac +- 10% 50/60 Hz...
  • Page 23: Control Unit - For C (Double Hot Air Duct) Models

    CONTROL UNIT - FOR C (DOUBLE HOT AIR DUCT) MODELS LINE (230V 50Hz) Exhaust Fan Heating Fan Encoder Heating Fan 2 Heating Fan 3 Safety Micro Thermostat Pressure Switch Remote Room Thermostat Auger Remote Room Thermostat 2 Ignition Sonda Fumi Resistance Flowmeter (FCS) Emergency Control Panel...
  • Page 24: Maintenance

    INSTRUCTIONS! Thanking you for choosing our product, Moretti Fire s.r.l. invites you to MORETTI DESIGN IS NOT RESPONSIBLE FOR DAMAGE TO consult the user manual and to read the following warranty conditions PEOPLE, ANIMALS OR THINGS CAUSED BY A NON-COMPLIANCE The manufacturer provides the customer with a 24 month period OF THE FOLLOWING INDICATIONS.
  • Page 25 www.morettidesign.it assistenzastufe@morettidesign.it e mail: assistenzastufe@morettidesign.it...
  • Page 26 Allegare copia della fattura d’acquisto / Enclose invoice copy...
  • Page 28 Moretti Fire s.r.l. Contrada Tesino 50 63065 Ripatransone (AP) ITALY Tel. +39073590444 Fax +390735907452 www.morettidesign.it info@morettidesign.it The Moretti fire s.r.l. assumes no responsibility for any errors in this manual and the right to modify without notice features of its products REV.

Table of Contents

Save PDF