Moretti Design AQUA User Manual

Moretti Design AQUA User Manual

Hydro stove

Advertisement

AQUA
USER MANUAL
HYDRO STOVE
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AQUA and is the answer not in the manual?

Questions and answers

Edwin Howlett
January 28, 2025

M pellet Burner saying no signal

Subscribe to Our Youtube Channel

Summary of Contents for Moretti Design AQUA

  • Page 1 AQUA USER MANUAL HYDRO STOVE...
  • Page 2: Table Of Contents

    INDEX INTRODUCTION Time and date General safety warnings Calibration (models with FCS) DESCRIPTION Calibration (models without FCS) Identification Monitor Description of the stove Load INSTALLATION Clean Supply conditions and unpacking Language Assembling Settings Combustion air System menu Combustion air for a hermetic installation EMERGENCY CONTROL PANEL Fume exhaust USER MENU 1...
  • Page 3: General Safety Warnings

    All regulations regarding the installation and use of the hydro stove, including those referring to National and European On all Moretti Design products, at the end of the assembly line a standards must be complied with. scrupulous check-up followed by a combustion test is carried out.
  • Page 4: Description Of The Stove

    The advanced software allows for the user a more simple and immediate comprehension of the heaters functions. The presence of a thermostat on all Moretti Design products allow the EXAMPLE user to program the on/off switching function of the stove. The large fuel tank, allows fuel fillings conveniently diluted over time.
  • Page 5 CHIMNEY FLUE INSIDE AN OLD CHIMNEY EXTERNAL CHIMNEY FLUE CORRECT CORRECT INSTALLATION INSTALLATION CHIMNEY WITH PROTECTION COVER PLATE INSULATION INSULATED CHIMNEY FLUE OPEN 45° CURVE CHIMNEY FLUE INSULATED “T” “T” WITH WITH INSPECTION INSPECTION CAP CHIMNEY FLUE WITHOUT “T” CHIMNEY FLUE THROUGH OUTSIDE WALL IMPROPER IMPROPER INSTALLATION...
  • Page 6: Installing The Remote Thermostat In The Environment

    Installing the remote thermostat in the environment CHIMNEY FLUE Moretti Design hydro stoves allow for the installation of a on/off remote thermostat. The connection for the remote thermostat is located on the back of the stove straight under the power connector, it has a two pin connector coupling with two buttons, one black and one red.
  • Page 7: Connecting To A System With Zone Valves

    Moretti Design, who will submit it to all the check ups required by current stove or on the radiator.
  • Page 8: First Ignition

    FIRST IGNITION Fill the fuel tank with wooden pellets. Open the lid and Caution: The first ignition must be carried out by MORETTI DESIGN then pour the fuel in. It is recommended to close the pellet qualified personnel that must also perform an overall check up of the tank lid properly.
  • Page 9: Fcs (Fire Control System)

    FCS (Fire Control System) NON OPTIMAL combustion, the flame is too stretched and a large amount of burning pellets are blown out of the burner. It is an automatic combustion control system that maintains the products high efficiency. The system •...
  • Page 10: Display Radio

    Button description DISPLAY RADIO Introduction Function Description Button The display radio (black) is a wireless device for the stove to which it is associated with and through it, it is possible Pressing the button when the main screen is to control and monitor the systems functions in real time. active, the device will continue to function Sleeping but will “fall asleep”...
  • Page 11: Normal

    Run Mode Fuel After the ignition, the system goes into Run Mode. During this phase the Menu for selecting fuel type (type pellets). heating fan is activated and the system operates on the set combustion power level. Remote Keyboard Menu that enables or disables the remote keyboard if connected to the Modulation hydro stove.
  • Page 12: Time And Date

    • Select hours, minutes and date with Weekly It modifies directly the on/off switching time frames and there are 3 • Enter edit mode (flashing cursor) by pressing SET. phases throughout the week. • Modify the selected value with and save the setting by Program Weekly pressing SET.
  • Page 13: Monitor

    Fan Calibration: Menu for setting the combustion air Fan speed. There Load are 10 levels, 5 to increase and 5 to decrease, the 0 level is the The menu allows the manual filling of the auger. The stove must be manufacturers default value.
  • Page 14: System Menu

    Set Contrast: Menu for adjusting the contrast on the display. Calibration Thermostat Manage Radio Monitor Standby Calibration Thermostat Manage Radio Standby Load Radio Standby Contrast Monitor Radio Test Radio Test Clean Load Change Code Change Code Language Clean Active Set Contrast Set Contrast Language Settings...
  • Page 15: Emergency Control Panel

    Operating status shown EMERGENCY CONTROL PANEL Status Description CHEc Check up On 1, On 2, On 3, On 4 Ignition On 5 Stabilization Modulation StbY Standby Normal SAF/Erxx Safety Turn off Ignition recover Alt/Erxx Block Other messages Button description Code Description Click Press and hold...
  • Page 16: User Menu 2

    Press with a simple click the P3 button: the Display D2 starts flashing. By USER MENU 2 pressing the button several times again, it is possible to change the To access the menu, press and hold at the same time the P3 and P4 power setting according to the available values.
  • Page 17 In the Daily program it is possible to set 3 time frames for every single day of the week: Mo (monday), tU (tuesday), WE (wednesday), tH (thursday), Fr (friday), SA (saturday), Su (sunday). Make sure that in Modality (ModE) the item Gior (Daily) has been selected.
  • Page 18: Errors And Messages

    ERRORS AND MESSAGES Code Description Cause Operations to be performed Solutions Reset the thermostat (page 21), If the pump is broken call an PUMP BLOCKED OR BROKEN unblock and verify the proper authorized technician function of the pump Reset the thermostat (page 21), AIR IN THE SYSTEM unblock and verify if there is any air Discharge the air from the system...
  • Page 19 Code Description Cause Operations to be performed Solutions Unblock and turn on the stove, if Turn off due to the error reoccurs, then the If the error persists, contact an Er08 NON SETTING ENCODER Encoder error exhaust fan or control unit is authorised technician broken Check the pressure of the heating...
  • Page 20: Control Unit

    CONTROL UNIT Micro Switch (Burner Cleaner) ONLY FOR PLUS CLEAN MODELS LINE (230V 50Hz) Exhaust Fan Heating Fan Burner Cleaner Motor Encoder ONLY FOR PLUS CLEAN MODELS Ignition Resistance Cleaner Motor CLEAN AND PLUS CLEAN MODELS Pressure Sensor Safety Thermostat Resetting Thermostat Pressure Switch Micro Switch...
  • Page 21 Function Main Power Supply 230Vac ± 20% Exhaust Fan Heating Fan (NO TECNIKA) Valve 2 ((Motor for Burner Cleaner - PLUS CLEAN) Ignition Resistance 9-10 Heat Exchanger Cleaner Motor (CLEAN - PLUS CLEAN) Pellet Tank Safety Thermostat 11-12 Safety Resetting Thermostat (Short-circuit if not used) Pressure Switch 13-14...
  • Page 22: How To Reset The Safety Thermostat (Er01)

    PLEASE FOLLOW CAREFULLY THE FOLLOWING CLEANING INSTRUCTIONS! MORETTI DESIGN IS NOT RESPONSIBLE FOR DAMAGE TO PEOPLE, ANIMALS OR THINGS CAUSED BY A NON-COMPLIANCE OF THE FOLLOWING INDICATIONS. In addition to the annual maintenance that must be carried out by...
  • Page 23: Fire Protection

    To ensure that the hydro stove always has an optimal combustion A non received or incomplete warranty card voids the warranty. and to avoid malfunctions, frequent cleaning operations must be carried out. The frequency of these operations may vary according Warranty conditions to the time of use of the stove and quality of the pellets.
  • Page 24: Plumbing Configuration

    PLUMBING CONFIGURATION It is possible to integrate the hydro stove to one of the following hydraulic system configurations considered most suitable. To set the configuration, an authorized technician must be contacted. CONFIGURATION 0 The configuration show in the figure is set. This is the standard setting. If the domestic hot water kit is installed, it is not necessary to change the setting on the hydro stove.
  • Page 25 CONFIGURATION 1 The configuration shown in the figure is set. Connections on the control unit Pump (P2) Flow Switch (FL) Connections on the heating system (the following schematic is only illustrative) domestic cold water domestic hot water heat heating system exchanger sphere valve...
  • Page 26 CONFIGURATION 2 The configuration shown in the figure is set. Connections on the control unit Probe (S2) Electrovalve (P2) Puffer/Boiler 23: towards heating system 24: towards domestic hot water Connections on the heating system (the following schematic is only illustrative) domestic cold water Boiler...
  • Page 27 CONFIGURATION 3 The configuration shown in the figure is set. Connections on the control unit Probe (S2) Pump (P2) Puffer/Boiler Connections on the heating system (the following schematic is only illustrative) domestic cold water Boiler heating system domestic hot sphere water valve sphere...
  • Page 28 CONFIGURATION 4 The configuration shown in the figure is set. Connections on the control unit Probe (S2) Puffer/Boiler Connections on the heating system (the following schematic is only illustrative) Puffer sphere valve sphere valve sphere sphere valve valve non return valve The system includes: the hydro stove Boiler Probe (S1), the hydro stove Pump (P1), Boiler/Puffer Probe (S2).
  • Page 29 www.morettidesign.it assistenzastufe@morettidesign.it e mail: assistenzastufe@morettidesign.it...
  • Page 30 Allegare copia della fattura d’acquisto / Enclose invoice copy...
  • Page 32 Moretti Fire s.r.l. Contrada Tesino 50 63065 Ripatransone (AP) ITALY Tel. +39073590444 Fax +390735907452 www.morettidesign.it info@morettidesign.it The Moretti fire s.r.l. assumes no responsibility for any errors in this manual and the right to modify without notice features of its products REV.

Table of Contents

Save PDF