Emergency Control Panel; User Menu 1 - Moretti Design AQUA User Manual

Hydro stove
Table of Contents

Advertisement

EMERGENCY CONTROL PANEL

L1
ESC
P1
D2
P3
L4
Button description
Click
P1
Monitor / Exit Menu
Modify Thermostat (+) /
P2
Increase value
Modify Combustion
P3
Power / Save data
Modify Thermostat (-) /
P4
Decrease value
Symbol description
Led
Symbol
L1
Led On: Pump On
L2
Led On: Auger On
L3
Led On: Ignition Resistance On
L4
Led On: Thermostat Temperature Reached
L5
G
Led On: Daily Programmed
L6
S
Led On: Weekly Programmed
L7
W
Led On: Week-End Programmed
Values displayed on the main screen
Display
D1
Time, Operating Status, Error, Menu, Submenu, Values.
D2
Power, Code.
D3
Recipe.
D4
Main temperature, Code.
L2
L3
D1
D3
D4
G
S
W
L5
L6
L7
Press and hold
Switch On / Switch Off / Reset
Block
Pellet Load Setting
Manual Pellet Load
Exhaust Fan Setting
Description
Description
Operating status shown
Status
CHEc
On 1, On 2, On 3, On 4
On 5
Mod
P2
StbY
P4
SAF/Erxx
OFF
rEc
Alt/Erxx
Other messages
Code
Sensor anomaly. This message appears during the Check-
up phase and indicates that the temperature read is equal
Sond
to the minimum value (0°C) or the maximum value. Check
if the sensors are detached (0°C), or have short-circuited.
Hi
Water temperature above 99 °C.
Message that indicates the achievement of the scheduled
SErU
functioning hours. Call an authorized technician
Message that indicates the achievement of the scheduled
PULi
functioning hours. The stove needs to be serviced.

USER MENU 1

Monitor
Press with a simple click the P1 button: the first value tA will appear on
the Display. In order to read the other values keep pressing with a simple
click the P1 button.
Codice
Puffer Temperature (visible only if configuration 2,3 or 4 is
tC
used)
tF
Exhaust fume temperature
UF
Exhaust fan speed (RPM/Volt)
Au
Auger on time (s)
PA
Water preassure (mbar)
FL
Primary air flow
tCL
Hours till next maintenance clean (h)
FUnC
Function modality Summer (Est) / Winter (InU)
FC
Firmware Code: FYSD01000139.00.00
327
Manufacturer product code: 0Y.0X
Combustion Power Setting
Description
Check up
Ignition
Stabilization
Modulation
Standby
Normal
Safety
Turn off
Ignition recover
Block
Description
Descrizione
14