ZONE SETUP
Selecting the Operation Mode
Zone Setup allows you to change the operation mode of a zone,
specify if a selected load is to be controlled by Daylighting and to
bind loads to the LMLS-600.
L M L S - 6 0 0
0 2 9 7 7 9 5 5 8 4
Z o n e S e t u p
C a l i b r a t i o n
Z o n e S e t t i n g s
A d v a n c e d S e t t i n g s
C o n t r o l M o d e
Press
Select
Z o n e S e t u p
L M L S - 6 0 0
O p e r a t i o n :
< B i - L e v e l >
C O N T I N U E
Press Left/Right arrow to choose the
desired operation mode for the Zone:
<Switched>, <Bi-Level>,
<Tri-Level> or <Dimmed>
After choosing Zone Setup and pressing Select, the current
operation mode is displayed. This can be changed to Switched,
Bi-Level, Tri-Level, or Dimmed.
Switched
Switched mode provides ON/OFF switching within the daylighting
zone controlled by the photosensor.
Load 1 - OFF 0%
Load 1 - ON 100%
Bi-Level
Bi-level mode provides three light levels within the daylighting
zone controlled by the photosensor by using 2 load circuits.
Load 1 - OFF
Off = 0%
Load 2 - OFF
Load 1 - ON
Med = 50%
Load 2 - OFF
Load 1 - ON
Max = 100%
Load 2 - ON
Tri-Level
Tri-level mode provides four light levels within the daylighting zone
controlled by the photosensor by using 2 load circuits.
Load 1 - OFF
Off = 0%
Load 2 - OFF
Load 1 - OFF
Low = 33%
Load 2 - ON
Load 1 - ON
High = 66%
Load 2 - OFF
Load 1 - ON
Max = 100%
Load 2 - ON
P o i n t t o A n y I R
e n a b l e d d e v i c e o n
t h e n e t w o r k
P r e s s ' S e l e c t '
C O N T I N U E
Point and
Press Select
Z o n e S e t u p
L M L S - 5 0 0
P o i n t t o a n y I R
B i - L e v e l
e n a b l e d d e v i c e o n
t h e N e t w o r k
P r e s s ' S e l e c t '
N E X T
P R I O R
D O N E
Point and
Press Select
Dimmed
Dimmed mode provides continuous dimming within the daylight
zone controlled by the photosensor.
Load 1 - ON 1%
Load 1 - ON 100%
Load Assignments
To do load binding, the load needs to be assigned.
Z o n e S e t u p
L M L S - 6 0 0
B i - L e v e l
L o a d :
D a y l i g h t L o a d :
N E X T
P R I O R
D O N E
Load 1: Press Left/Right
arrow to select
Yes or No
For Bi-level and Tri-level only, press the Down arrow for On When
to display.
Z o n e S e t u p
L M L S - 6 0 0
B i - L e v e l
L o a d :
D a y l i g h t L o a d :
< Ye s >
O n W h e n
< M a x >
:
N E X T
P R I O R
D O N E
N E X T
P R I O R
D O N E
Bi-level and Tri-Level only:
Press the Down arrow for
'On When' to appear
Press Left/Right arrow:
For Bi-Level select
Med & Max or Max
For Tri-Level select
Low & Max or High & Max
Next
To continue to assign Daylight Load binding to load 2, choose
NEXT.
Z o n e S e t u p
L M L S - 6 0 0
B i - L e v e l
L o a d :
D a y l i g h t L o a d :
< Ye s >
O n W h e n :
< M e d & M a x >
N E X T
P R I O R
D O N E
Choose
Press
NEXT
Select
Z o n e S e t u p
L M L S - 6 0 0
Tr i - L e v e l
L o a d :
< Ye s >
D a y l i g h t L o a d :
O n W h e n :
< L o w & M a x >
N E X T
P R I O R
D O N E
Bi-level and Tri-Level only:
Press the Down arrow for
'On When' to appear
Press Left/Right arrow:
For Bi-Level select
Med & Max or Max
For Tri-Level select
Low & Max or High & Max
6
Depending on the Operation Mode,
1
the screen display will be Bi-Level,
< Ye s >
Tri-Level, Switched or Dimmed
Z o n e S e t u p
B i - L e v e l
1
L o a d :
D a y l i g h t L o a d :
O n W h e n :
N E X T
P R I O R
Choose
NEXT
P o i n t t o a n I R
e n a b l e d d e v i c e o n
1
t h e N e t w o r k
P r e s s ' S e l e c t '
Point and
Press Select
Zone settings for the
2
next load is diplayed.
1%.
.
.
.
.
100%
L M L S - 6 0 0
1
< Ye s >
< M e d & M a x >
D O N E
Press
Select

Advertisement

Table of Contents
loading

Table of Contents