ENGLISH
9. BUTTONS:
10. DISPLAY: shows the various menus and the selected functions.
11. SENSITIVITY KNOB: The unit works to rhythm of the beat when used in standalone or master/slave
mode. With this knob you can set the input sensitivity of the build-in microphone.
12. INTERNAL MICROPHONE: The built-in microphone is used to synchronize the show to the beat of the
music.

OVERHEAD RIGGING

• Important: The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and/or damage to property. Overhead rigging requires
extensive experience! Working load limits should be respected, certified installation materials
should be used, the installed device should be inspected regularly for safety.
• Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.
• Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The
fixture must be fixed at least 50cm from surrounding walls.
• The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.
• Before rigging make sure that the installation area can hold a minimum point load of 10times the device's
weight.
• Always use a certified safety cable that can hold 12 times the weight of the device when installing the unit.
This secondary safety attachment should be installed in a way that no part of the installation can drop
more than 20cm if the main attachment fails.
• The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!
• Don't cover any ventilation openings as this may result in overheating.
• The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.
JB SYSTEMS®
[MENU]
To browse the different menu options
[UP]
To go forward in the selected functions or to increase a value
[DOWN]
To go backward in the selected functions or to decrease a value
[ENTER]
To confirm the selected functions