HELIOS COMBO SPH3600/5000-BL
This chapter introduces inverter startup, shutdown and monitoring setting.

5.1 Opearaion Announcements

⚫ Load requirements in the BACK UP port is as below:
Resistive load≤2.5kw;
Capacitive load≤1.5kvar;
Inductive load≤1.5kvar.
⚫ There may exists suspended voltage between live wire and neutral wire with grounding wire in
the BACKUP port and GRID port. Don't touch live wire and neutral wire directly.
⚫ If there has overload protection or short circuit protection, power down inverter and then power it
on again.

5.2 Turn on Inverter

Step 1
Switch on AC output switch.
Step 2
Switch on DC input switch.
Step 3
Switch on battery switch.
----End

5.3 Turn off Inverter

Step 1
Switch off all switches.
Step 2
Wait all indicators are off.
----End

5.4 Monitoring Setting

If it needs to perform monitoring setting, connect PC with inverter and download WiseEnergy in the
official website.

5 Operation Instruction

33