Increasing your DC cable size will help improve the situation.
Our company recommends the following cables for optimum inverter performance
Model No
RM -PSW245KVA/E
RM -PSW485KVA/E
RM -PSW1105KVA/E
RM -PSW2205KVA/E
Also, use only high quality copper wiring and keep cable length short from 3-6 feet.

2-7 Inverter Operation:

To operate the power inverter, turn it on using the ON/OFF switch on the front panel. The
power inverter is now ready to deliver AC power to your loads.
If you are operating several loads from the power inverter, turn them on separately after the
inverter has been turned on.
This will ensure that the power inverter does not have to deliver the starting currents for all
the loads at once.
2-7-1 Controls and indicators:
The ON / OFF switch turns the control circuit in the power inverter on and off.
The Inverter operates from an input voltage ranging from :
20 to 32 VDC for 24V models
42 to 62VDC for 48V models
90 to 140VDC for 110V models.
180 to 275VDC for 220V models
The Inverter will indicate high and low DC voltage conditions as follows:
Model
RM-PSW245KVA/E
RM-PSW485KVA/E
RM-PSW1105KVA/E
RM-PSW2205KVA/E
Note: Inverter will automatically start operating when input returns back to normal voltage
range, as per 2-7-1
2-7-2 Output Voltage Indicator:
2-7-3 Output Current Indicator
2-7-4 Output Watts Indicator
DC Input over
voltage shut-down
32VDC
62VDC
140VDC
275VDC
LED displays light on VAC as show as output Voltage value
LED displays light on AMP as show as output current value
LED displays light on Watts as show as output Watts value
Wire AWG
#4/0
#2/0
#4
#6
DC Input over
DC Input under
voltage alarm
voltage alarm
31VDC
61VDC
135VDC
270VDC
11
Inline Fuse
300A
200A
100A
50A
DC Input under
voltage shut-down
21VDC
20VDC
43VDC
42VDC
95VDC
90VDC
185VDC
180VDC