  • Page 1 2U x 19" rack mount - PSW5KVA Series Pure Sine Wave Inverter Instruction Manual -PSW245KVA/E -PSW485KVA/E -PSW1105KVA/E -PSW2205KVA/E REV ( 22-05-2020 ) www.heliosps.com Email - New Zealand: sales@heliosps.co.nz - Australia: sales@heliosps.com.au - Asia & Middle East: sales@heliosps.asia...
  • Page 2: Table Of Contents

    List of Contents Page Features Application Electrical performance Mechanical drawings Introduction Front panel operations Rear panel operations Installation Quick hook – up and testing AC safety grounding Making DC wiring connections Inverter operation Cooling fan working code Maintenance Troubleshooting guide Warranty Important safety striations General safety precautions...
  • Page 3: Application

    Features R Load Pure sine wave output (THD < 3%) By pass function Output frequency: 50 / 60Hz switch RS-232 interface / remote controls port / Wire connection to PC Wired Remote Control Loading controlled cooling fan Advanced microprocessor Protection: Input Undervoltage Input Overvoltage Overload Short circuit...
  • Page 4: Electrical Performance

    Electrical Performance Specification Model RM-PSW RM-PSW RM-PSW RM-PSW RM-PSW RM-PSW RM-PSW RM-PSW Item 245KVA 485KVA 1105KVA 2205KVA 245KVAE 485KVAE 1105KVAE 2205KVAE Continuous Output Power 5000W Maximum Output Power 5200W (3 mins) Surge Rating 10000W Input Voltage 110V 220V 110V 220V 20-32 42-62 90-140...
  • Page 5: Mechanical Drawings

    1-3 Mechanical Drawings...
  • Page 6: Introduction

    2 Introduction: The power inverter series are the member of the most advanced line of mobile AC power systems available. To get the most out of the power inverter, it must be installed and used properly. Please read the instructions in this manual before installing and using this model. 2-1 Front Panel Operation: 2-1-1 Front view: 2-1-2 ON / OFF switch:...
  • Page 7: Rear Panel Operations

    2-2 Rear Panel Operation: 2-2-1 Ventilation openings: Do not obstruct, allow at least 3 inch for air flow. 2-2-2 AC input switch: This switch is to be operated by qualified personnel only. 2-2-3 Battery terminals: Connect to 24V/48V/110V/220V battery or other 24V/48V/110V/220V power Source. 【+】is positive,【-】is negative.
  • Page 8: Installation

    See Appendix A for RS232 protocol • WARNING! Any damages caused by using incorrect RS232 cable will be outside of our warranty scope. If you are not sure which one is correct RS232 cable, please purchase the correct RS232 cable from us directly.
  • Page 9: Quick Hook - Up And Testing

    2-3-3 Safe – Do not install in a battery compartment or other areas where flammable fumes may exist, such as fuel storage areas or engine compartments. 2-3-4 Ventilated – Allow at least one inch of clearance around the inverter for air flow. Ensure the ventilation openings on the rear and bottom of the unit are not obstructed.
  • Page 10: Ac Safety Grounding

    2-4-3 Before proceeding further, carefully check that cable you have just connected negative terminal of inverter to the negative output power source. CAUTION! Reverse polarity connection will blow a fuse in inverter and may permanently damage the inverter. Damage caused by reversing polarity connection is not covered by our warranty.
  • Page 11: Making Dc Wiring Connections

    230V models: There is no connection made inside the YK-PSW5KVA/E Inverter from either the line or neutral conductor to the safety ground. Ground Fault Circuit Interrupters (GFCI’S): Installations in Recreational Vehicles (for North American approvals) will require GFCI protection of all branch circuit connected to the AC output of the hardwire terminal equipped inverter.
  • Page 12: Inverter Operation

    Increasing your DC cable size will help improve the situation. Our company recommends the following cables for optimum inverter performance Model No Wire AWG Inline Fuse RM -PSW245KVA/E #4/0 300A RM -PSW485KVA/E #2/0 200A RM -PSW1105KVA/E 100A RM -PSW2205KVA/E Also, use only high quality copper wiring and keep cable length short from 3-6 feet. 2-7 Inverter Operation: To operate the power inverter, turn it on using the ON/OFF switch on the front panel.
  • Page 13 2-7-5 Input DC Voltage Indicator LED displays light on VDC as show as input DC voltage value 2-7-6 Temperature Indicator LED displays light on TEMP as show as internal operating temperature value 2-7-7 Output Frequency AC Indicator LED displays light on Hz as show as output frequency value Please have the accuracy of 6 functions of display, as below: Function WATT...
  • Page 14: Cooling Fan Working Code

    2-7-11 Overload protection indicator: (OLP) The overload indicator indicates that the power inverter has shut itself down. When output voltage over continue power, then must return to operate manually. Cooling fan working code: Cooling fan of inverter is through detecting output power and over temperature situation to work.
  • Page 15: Troubleshooting Guide

    4 Troubleshooting guide: WARNING! Do not open or disassemble the inverter. Attempting to service the unit yourself may result in a risk of electrical shock or fire. Common problems – television interference: Operation of the power inverter can interfere with television reception on some channels, If this situation occurs, the following steps may help to alleviate the problems.
  • Page 16: Warranty

    5 Warranty : We warrant this product against defects in materials and workmanship during warranty period and will repair or replace any defective power inverter when directly returned (postage paid) to us. This warranty will be considered void if the unit has suffered any obvious damage by natural and man-made factors, or alteration either internal or external and does not cover damage arising from improper use such as plugging the unit into an unsuitable power sources attempts to operate products with excessive power consumption requirement, or use in...
  • Page 17: Precautions When Working With Batteries

    6-2 Precautions When Working with Batteries 6-2-1 If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters eye, immediately flood eye with running cold water for at lease 20minutes and get medical attention immediately. 6-2-2 NEVER smoke or allow a spark or flame in vicinity of battery or engine.
  • Page 18: Rs232 Protocol

    RS232 Protocol A. COMMUNICATION PROTOCOL: ( SF / RM Series Inverters ) 1. Status Inquiry: Computer: Q1<cr> INV INV data stream, such as (MMM.M NNN.N PPP.P QQQ RR.R S.SS TT.T b7b6b5b4b3b2b1b0<cr> INVERTERdata stream : There should be a space character between every field is list as followed: a.
  • Page 19 I/P fault voltage is 140.0V.------------------(SPEC) O/P voltage is 208.4V. O/P current is 34%. I/P frequency is 59.9 HZ. Battery voltage is 2.05V. Temperature is 35.0 degrees of centigrade. Helios Power Solutions: Email - Australia: sales@heliosps.com.au - Singapore: sales@heliosps.asia - New Zealand: sales@heliosps.co.nz...