Helios COMBO SPH3600-BL SERIES User Manual page 32

Multiple mode inverter
Table of Contents

Advertisement

HELIOS COMBO SPH3600/5000-BL
Figure4-11 Negative wire
Step 3
Draw the positive wire and negative wire through the corresponding sealing nuts respectively.
Step 4
Insert the positive wire and negative wire into the positive metal terminal and negative metal terminal
respectively. Crimp the metal terminals firmly by crimping pliers, as shown in Figure4-12 and Figure4-
13.
Figure4-12 Crimp the positive metal terminal
Figure4-13 Crimp the negative metal terminal
Step 5
Insert the positive wire and negative wire into the corresponding insulation crust respectively. If there
has a click sound, it means it have been inserted properly.
Step 6
Tighten the sealing nuts of positive connector and negative connector to the corresponding insulation
crusts respectively.
Step 7
Insert the positive connector and negative connector into the ports marked with "+" and "-" in the
inverter respectively. If there has a click sound, it means it have been inserted properly, as shown in
Figure4-14 and Figure4-15.
Figure4-14 Connect with the positive pole of DC input
Figure4-15 Connect with the negative pole of DC input.
7mm