Intel® Light-Guided Diagnostics
Color
State
Amber
~1 Hz blink
Amber
Solid on
96
Criticality
Non-critical - System is
operating in a degraded state
with an impending failure
warning, although still
functioning
Critical, non-recoverable –
System is halted
Technical Product Specification
Description
Non-fatal alarm – system is likely to fail:
Critical threshold crossed – Voltage, temperature
(including HSBP temp), input power to power
supply, output current for main power rail from
power supply and PROCHOT (Therm Ctrl) sensors.
VRD Hot asserted.
Minimum number of fans to cool the system not
present or failed
Hard drive fault
Power Unit Redundancy sensor – Insufficient
resources offset (indicates not enough power
supplies present)
In non-sparing and non-mirroring mode if the
threshold of correctable errors is crossed within
the window
Fatal alarm – system has failed or shutdown:
CPU CATERR signal asserted
MSID mismatch detected (CATERR also asserts for
this case).
CPU 1 is missing
CPU Thermal Trip
No power good – power fault
DIMM failure when there is only 1 DIMM present
and hence no good memory present.
Runtime memory uncorrectable error in non-
redundant mode.
DIMM Thermal Trip or equivalent
SSB Thermal Trip or equivalent
CPU ERR2 signal asserted
BMC/Video memory test failed. (Chassis ID shows
blue/solid-on for this condition)
Both uBoot BMC firmware images are bad. (Chassis
ID shows blue/solid-on for this condition)
240VA fault
Fatal Error in processor initialization:
Processor family not identical
o
Processor model not identical
o
Processor core/thread counts not identical
o
Processor cache size not identical
o
Unable to synchronize processor frequency
o
Unable to synchronize QPI link frequency
o
Uncorrectable memory error in a non-redundant
mode
Revision 1.37