Figure 48. High-Level Fan Speed Control Process - Intel S2600KPFR Product Specifications

S2600kp series
Table of Contents

Advertisement

Technical Product Specification
Front panel temperature sensor
Baseboard temperature sensors
CPU DTS-Spec margin sensors
DIMM thermal margin sensors
Exit air temperature sensor
Global aggregate thermal margin sensors
SSB (Intel
®
C610 Series Chipset) temperature sensor
On-board Ethernet controller temperature sensors (support for this is specific to the
Ethernet controller being used)
Add-in Intel
Power supply thermal sensors (only available on PMBus*-compliant power supplies)
A simple model is shown in the following figure which gives a high level graphic of the fan
speed control structure creates the resulting fan speeds.
Policy: CLTT,
Acoustic/Performance,
Auto-Profile
configuration
Front Panel
Processor
Margin
(Chipset, Temp,
9.3.14.5.1 Processor Thermal Management
Processor thermal management utilizes clamp algorithms for which the Processor DTS-Spec
margin sensor is a controlling input. This replaces the use of the (legacy) raw DTS sensor
reading that was utilized on previous generation platforms. The legacy DTS sensor is retained
only for monitoring purposes and is not used as an input to the fan speed control.
Revision 1.37
®
SAS/IO module temperature sensor(s) (if present)
Memory
Throttle
Settings
Resulting Fan
Speed
Other Sensors
etc..)

Figure 48. High-level Fan Speed Control Process

Platform Management
Intrusion
Fan Failure
Power Supply
Failure
Policy
Events
Sensor
System Behavior
119