NPort IAW5x50A-6I/O
Alias
Default
Options
Description
ATTENTION
Serial communication settings should match the attached serial device. Check the communication settings in
the user's manual for your serial device.

Baud rate

Default
Options
Description
Parity
Default
Options
Description
Data bit
Default
Options
Description
Stop bit
Default
Options
Description

Flow control

Default
Options
Description
FIFO
Default
Options
Description
Interface
Default
Options
Description
free text (e.g., "Secondary console connection")
This is an optional free text field to help you differentiate one serial port from another. It does
not affect operation of the NPort device server.
115200
50, 75, 110, 134, 150, 300, 600, 1200, 1800, 2400, 4800, 9600, 19200, 38400, 57600,
115200, 230400, 460800, 921600, Other
This field specifies the baudrate for the serial port. Nonstandard baudrates are supported
through the "Other" setting. When set to "Other", you may manually enter a baudrate of your
choice, up to 921600.
50 to 921600: The serial port will operate at the specified baudrate
Other: The serial port will operate at a baudrate that is manually entered by the user.
None
None, Odd, Even, Space, Mark
This field specifies the type of parity bit used for each character frame.
8
5, 6, 7, 8
This field specifies the number of data bits used to encode each character of data.
1
1, 1.5, 2
This field specifies the number of stop bits used for each character frame.
RTS/CTS
None, RTS/CTS, XON/XOFF, DTR/DSR
This field specifies the type of flow control used by the serial port.
Enable
Enable, Disable
This field specifies whether the serial port will use the built-in FIFO. A 128-byte FIFO is
provided to each serial port for both Tx and Rx directions. To prevent data loss during serial
communication, this should be set to Disabled if the attached serial device does not have a
FIFO.
RS-232
RS-232, RS-422, RS-485 2-wire, RS-485 4-wire
This field specifies the type of interface the serial port will use.