12.1 Performance of Other Ethernet Communications at the Time of Cyclic Communication
*2: RPI is measured with the following settings.
pps
RPI
0 pps
The EtherNet/IP function is set to Invalid.
Connections 1 to 3
2500 pps
Connections 4 to 66
Connection 1
5000 pps
Connections 2 to 66
Connections 1 to 3
7500 pps
Connections 4 to 66
Connections 1 to 65
10000 pps
Connection 66
The Ethernet communication (MEWTOCOL-DAT) between FP7 (Ethernet communication
device) and FP7 (Scanner) is performed as follows.
Send/Receive
Communication protocol
Number of connections
Send (*3)
Receive (*4)
*3:
FP7 (Ethernet communication device) to FP7 (Scanner)
*4:
FP7 (Scanner) to FP7 (Ethernet communication device)
29 ms
28 ms
15 ms
14 ms
10 ms
9 ms
7 ms
8 ms
Details
MEWTOCOL-DAT
1
RECV instruction is issued. (2038 words are requested.)
Response data for RECV instruction is sent.