8. Principles of operation

(1) VL-50S
-E (Pull cord type)
2
• Operating mode (fan speed) can be switched from HI (High) to LO (Low) to OFF by using the switch with a
pull cord.
<Lighting status of the operation lamp under each operating mode>
Operating mode of the fan
Operation lamp (LED1)
(2) VL-50ES
-E (Wall switch type)
2
• Operating mode (fan speed) can be switched by using the control switch. Operations may vary depending
on the switches installed.
220/230/240 V is applied between HI and COM2
220/230/240 V is applied between LO and COM2
<Lighting status of the operation lamp under each operating mode>
Operating mode of the fan
Operation lamp (LED1)
(3) VL-50SR
-E (Remote controller type)
2
• Operating mode (fan speed) can be selected from HI (High), LO (Low), and Power ON/OFF by using the
remote controller.
• Operating mode (fan speed) can be switched from HI (High) to LO (Low) to OFF by using the operating
mode selection switch on the main unit.
<Lighting status of the operation lamps under each operating mode>
Operating mode of the fan
Operation lamp (LED201)
Operation lamp (LED202)
OFF
HI
LO
Off
Lit
Lit
HI (High)
LO (Low)
OFF
HI
LO
Off
Lit
Lit
OFF
HI
LO
Off
Off
Lit
Off
Lit
Off
─ 12 ─