Air-conditioners for building application - indoor unit

Advertisement

Quick Links

Air-Conditioners For Building Application

INDOOR UNIT

PFFY - P VKM-E (2)

INSTALLATION MANUAL

For safe and correct use, read this manual and the outdoor unit installation manual thoroughly before installing
the air-conditioner unit.
INSTALLATIONSHANDBUCH
Aus Sicherheitsgründen und zur richtigen Anwendung vor Installation der Klimaanlage die vorliegende Bedie-
nungsanleitung und das Installationshandbuch gründlich durchlesen.
MANUEL D'INSTALLATION
Avant d'installer le climatiseur, lire attentivement ce manuel, ainsi que le manuel d'installation de l'appareil exté-
rieur pour une utilisation sûre et correct.
INSTALLATIEHANDLEIDING
Lees deze handleiding en de installatiehandleiding van het buitenapparaat zorgvuldig door voordat u met het
installeren van de airconditioner begint.
MANUAL DE INSTALACIÓN
Para un uso seguro y correcto, lea detalladamente este manual de instalación antes de montar la unidad de
aire acondicionado.
MANUALE DI INSTALLAZIONE
Per un uso sicuro e corretto, prima di installare il condizionatore d'aria leggere attentamente il presente manuale
ed il manuale d'installazione dell'unità esterna.
MANUAL DE INSTALAÇÃO
Para uma utilização segura e correcta, leia atentamente este manual e o manual de instalação da unidade exte-
rior antes de instalar o aparelho de ar condicionado.
For use with the R410A
Bei Verwendung von R410A
A utiliser avec le R410A
Bij gebruik van R410A
Para utilizar con el R410A
FOR INSTALLER
FÜR INSTALLATEURE
POUR L'INSTALLATEUR
VOOR DE INSTALLATEUR
PARA EL INSTALADOR
PER L'INSTALLATORE
PARA O INSTALADOR
Uso del refrigerante R410A
Para utilizaçao com o R410A
R410A ile beraber kullanmak için
English (GB)
Deutsch (D)
Français (F)
Nederlands (NL)
Español (E)
Italiano (I)
Português (P)
Türkçe (TR)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PFFY-P VKM-E (2) and is the answer not in the manual?

Questions and answers

Summary of Contents for Mitsubishi Electric PFFY-P VKM-E (2)

  • Page 1: Indoor Unit

    Air-Conditioners For Building Application INDOOR UNIT PFFY - P VKM-E (2) For use with the R410A Uso del refrigerante R410A Bei Verwendung von R410A A utiliser avec le R410A Para utilizaçao com o R410A Bij gebruik van R410A R410A ile beraber kullanmak için Para utilizar con el R410A INSTALLATION MANUAL FOR INSTALLER...
  • Page 2: Table Of Contents

    Contents 1. Safety precautions ..................2 6. Embedding the indoor unit in a wall.............. 6 2. Installation location ..................2 ....................7 3. Installing the indoor unit................3 8. Test run ......................8 4. Refrigerant pipe ................... 4 9. Air outlet selection ..................9 ..................
  • Page 3: Installation Location

    3. Installing the indoor unit (mm) 3.1. Indoor unit mounting bracket installation Note: if possible. (Fig. 3-2) Fig. 3-1 Fig. 3-2 3.2. Indoor unit preparation Press the 2 positions indicated by the arrows and open the front grille. (Fig. 3-3) Open the front grille and remove the 2 screws.
  • Page 4: Refrigerant Pipe

    3. Installing the indoor unit (mm) 2) For right downward or left downward piping (Fig. 3-8) (The following figure is a view of the bottom of the indoor unit from above.) When the unit is installed on the wall. When the unit is installed on the floor. Fig.
  • Page 5 If neces- Fig. 5-1 Fig. 5-2 sary, contact your nearest Mitsubishi Electric representative for the optional parts to prevent this problem. Sloping downward No upward slope Accumulated drain water End of drain hose is immersed in water.
  • Page 6: Embedding The Indoor Unit In A Wall

    5. Drainage piping work pan. Fig. 5-4 Piping tape Refrigerant piping Drain hose in the hose. to the figure to the left.) Piping bent outward Push Fig. 5-5 6. Embedding the indoor unit in a wall 6.1. Embedding the indoor unit in a wall (Fig. 6-1) space.
  • Page 7: Electrical Work

    7. Electrical work 7.1. Indoor unit (Fig. 7-1) Remove the electrical cover. control lines. After connecting, secure the wires with the cord clamp. force. (PG connection or the like.) more) After wiring is completed, reinstall the parts in the reverse order of removal. Power supply terminal block (TB2) Transmission terminal block (TB5) or 60227 IEC 53.
  • Page 8: Test Run

    7. Electrical work 7.5. Setting addresses (Fig. 7-4) (Be sure to operate with the main power turned OFF.) 220V 240V CN43 over 10, and setting branch numbers. CN82 1 2 3 4 5 6 7 8 9 10 Match the indoor unit’s refrigerant pipe with the BC controller’s end connection SW14 SW12 SW11...
  • Page 9: Air Outlet Selection

    8. Test run Display (Horiz.) Swing Actual airflow direction cannot be set. 9. Air outlet selection With this function, air comes out simultaneously from the upper and lower air outlets so that the room can be cooled or heated effectively. This function is set using the switch SWC on the address board.
  • Page 10 ................74 ..........78 ..................74 ................79 ............... 75 ................80 ..................76 .......... 81 ..................77 (mm) 4 4 × 25 mm P20/25/32/40 Fig. 2-1...
  • Page 11 (mm) Fig. 3-1 Fig. 3-2 Fig. 3-3 Fig. 3-4 Fig. 3-5 Fig. 3-6 Fig. 3-7...
  • Page 12 (mm) Fig. 3-8 Fig. 3-9 Fig. 3-10 45°±2° R410A P20/25/32/40 14 - 18 49 - 61 Fig. 4-2...
  • Page 13 Fig. 4-3 Fig. 4-4 Fig. 4-5 Installing flush against a wall with molding For left or right piping Fig. 4-6 Fig. 5-1 Fig. 5-2 Fig. 5-3...
  • Page 14 Fig. 5-4 Fig. 5-5 Fig. 6-1 1 2 3 4 5 6 7 8 9 10 Fig. 6-2...
  • Page 15 Power supply terminal block (TB2) Outdoor unit terminal block (TB5) Wiring clamp Fig. 7-1 M1 M2 S Indoor controller board M1 M2 M1 M2 CN3A M1 M2 M1 M2 M1 M2 M1 M2 Fig. 7-3...
  • Page 16 220V 240V CN43 CN82 1 2 3 4 5 6 7 8 9 10 SW14 SW12 SW11 (10ths DIGIT) (1s DIGIT) (BRANCH No.) ON/OFF button Test run display Indoor liquid pipe temperature display ON/OFF lamp Power display TEST RUN COOL, HEAT Error code display SIMPLE Test run remaining time...
  • Page 17 Display (Horiz.) Swing Actual 220V 240V CN43 CN82 1 2 3 4 5 6 7 8 9 10 SW11 SW14 SW12 (10ths DIGIT) (1s DIGIT) (BRANCH No.) Note: Be sure to operate with the main power turned off. Description of operation Operation COOL Air flow...
  • Page 18 This product is designed and intended for use in the residential, commercial and light-industrial environment. Importer: Mitsubishi Electric Europe B.V. Capronilaan 46, 1119 NS, Schiphol Rijk, The Netherlands French Branch 25, Boulevard des Bouvets, 92741 Nanterre Cedex, France German Branch...

Table of Contents