(3) Dismount the main unit.
For VL-50ES
-E
2
[1] Remove the PCB case cover.
Unscrew the screws (one PTT screw 4×8, indicat-
ed by
, and one PP screw 3×8, indicated by
Reassembly precaution
Tightening torque for the screws: 1.1 N . m
[2] Disconnect the power cable and ground cable
from the main unit.
For both models
[3] Unscrew the screws (four special screws 4x10.5,
indicated by
), and dismount the main unit.
Precaution
Pay attention to unhook the main unit from the
unit fixing screw (one special screw 4x10.5, indi-
cated by
) on the mounting plate.
Reassembly precaution
Tightening torque for the screws: 1.1 N . m
).
Main unit
─ 19 ─
PCB case cover
Power cable
Cord clamp
Lead-in opening
Bush
Terminal block
Ground cable
Ground screw
* The figure shows VL-50ES