Question
I installed the Geyser and turned
power on but nothing is happening
I installed the Geyser, the first time
it engaged and operated for about
10 to 15 minutes after which it
switched off and the red light came
on.
Power was interrupted while the
Geyser was operating. After power
was restored, the Geyser is now in
standby mode.
My Geyser is going into Defrost
Mode frequently.
I moved the Geyser while it was
operating. Now there is a red light
and the Geyser won't run.
How do I adjust the temperature of
the water in my water tank.
The red light came on and the
Geyser switched off
There is a 5 minute time delay on the compressor or the
thermostat is not calling for heat.
Most likely during the install air remained in the system and the
pump inside the Geyser is air-bound. Push the red reset button
next to the power switch and open the drain valve slightly (there
may be a 5 minute delay in starting). This will allow the air to
escape together with some water (capture the water) allowing
the pump to operate normally.
The Geyser has a 5 minute compressor timer. After 5 minutes
have lapsed, the Geyser will go back into normal operation.
The Geyser is located in an area where the ambient temperature
is low (below 50°F) and the humidity is high. Check temperature.
Moving the Geyser while it is operating can cause a locked rotor
condition in the compressor. Push the red reset button next to
the power switch. The Geyser will now operate normally. (There
may be a 5 minute delay in starting)
Turn-off power to the water heater. Remove the water heaters
lower cover. Adjust the temperature with the thermostat on the
tank. Replace cover and turn power back on.
Push the red reset button next to the power switch. The Geyser
will now operate normally. (There may be a 5 minute delay in
starting). If the situation persists, turn the Geyser off and call
for service. Call technical support at Hubbell Electric Heater Co.
203-378-2659.