Supermicro SUPERSERVER 6018R-TD User Manual page 62

1u rackmount chassis
Table of Contents

Advertisement

S
S
UPER
ERVER 6018R-TD User's Manual
The options for Serial Port 1 are Auto, (IO=3F8h; IRQ=4), (IO=3F8h; IRQ=3, 4, 5,
6, 7, 9, 10, 11, 12), (IO=2F8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12), (IO=3E8h; IRQ=3,
4, 5, 6, 7, 9, 10, 11, 12), and (IO=2E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12).
The options for Serial Port 2 are Auto, (IO=2F8h; IRQ=3), (IO=3F8h; IRQ=3, 4, 5,
6, 7, 9, 10, 11, 12), (IO=2F8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12), (IO=3E8h; IRQ=3,
4, 5, 6, 7, 9, 10, 11, 12), and (IO=2E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12).
Serial Port 2 Attribute
Select SOL to use COM Port 2 as a Serial-Over-LAN (SOL) port for console redirec-
tion. The options are SOL and COM.
Serial Port Console Redirection
COM 1 Console Redirection
COM1 Console Redirection
Select Enabled to enable COM Port 1 for Console Redirection, which will allow a
client machine to be connected to a host machine at a remote site for networking.
The options are Disabled and Enabled.
*If this option is set to Enabled, the following items will become available
for configuration:
COM1 Console Redirection Settings
Terminal Type
This feature allows the user to select the emulation type for the target terminal
used for Console Redirection. Select VT100 to use the ASCII character set.
Select VT100+ to add color and function key support. Select ANSI to use the
extended ASCII character set. Select VT-UTF8 to use UTF8 encoding to map
Unicode characters into one or more bytes. The options are VT100, VT100+,
VT-UTF8, and ANSI.
Bits per second
Use this item to set the transmission speed, in bits per second, for COM1, which
is used in Console Redirection. Make sure that the same speed is used in the
host computer and the client computer. A lower transmission speed may be
required for long and busy lines. The options are 9600, 19200, 38400, 57600,
and 115200.
Data Bits
Use this feature to set the data transmission size, in bits, for Console Redirec-
tion. The options are 7 and 8.
7-24
Parity
A parity bit can be sent along with regular data bits to detect data transmission
errors. Select Even if the parity bit is set to 0, and the number of 1's in data bits
is even. Select Odd if the parity bit is set to 0, and the number of 1's in data bits
is odd. Select None if you do not want to send a parity bit with your data bits
in transmission. Select Mark to add a mark as a parity bit to be sent along with
the data bits. Select Space to add a Space as a parity bit to be sent with your
data bits. The options are None, Even, Odd, Mark, and Space.
Stop Bits
A stop bit indicates the end of a serial data packet. Select 1 Stop Bit for standard
serial data communication. Select 2 Stop Bits if slower devices are used. The
options are 1 and 2.
Flow Control
Use this item to set the flow control for Console Redirection to prevent data
loss caused by buffer overflow. Send a "Stop" signal to stop sending data when
the receiving buffer is full. Send a "Start" signal to start sending data when the
receiving buffer is empty. The options are None and Hardware RTS/CTS.
VT-UTF8 Combo Key Support
Select Enabled to enable VT-UTF8 Combination Key support for ANSI/VT100
terminals. The options are Disabled and Enabled.
Recorder Mode
Select Enabled to capture the data displayed on a terminal and send them as
text messages to a remote server. The options are Disabled and Enabled.
Resolution 100x31
Select Enabled for extended-terminal resolution support. The options are Dis-
abled and Enabled.
Legacy OS Redirection Resolution
Use this item to select the number of rows and columns used in Console Redi-
rection for legacy OS support. The options are 80x24 and 80x25.
Putty KeyPad
This feature selects Function Keys and KeyPad settings for Putty, which is a
terminal emulator designed for the Windows OS. The options are VT100, LINUX,
XTERMR6, SCO, ESCN, and VT400.