Supermicro SUPERSERVER 6018R-TD User Manual

1u rackmount chassis
Table of Contents

Advertisement

Quick Links

S
S
UPER
ERVER
®
6018R-TD
USER'S MANUAL
1.0a

Advertisement

Table of Contents
loading

Summary of Contents for Supermicro SUPERSERVER 6018R-TD

  • Page 1 UPER ERVER ® 6018R-TD USER’S MANUAL 1.0a...
  • Page 2 This manual is written for professional system integrators and PC technicians. It mentation, is the property of Supermicro and/or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly permitted by the terms provides information for the installation and use of the SuperServer 6018R-TD.
  • Page 3 Preface UPER ERVER 6018R-TD User's Manual Notes Chapter 5: Advanced Serverboard Setup Chapter 5 provides detailed information on the X10DRD-L serverboard, including the locations and functions of connections, headers and jumpers. Refer to this chapter when adding or removing processors or main memory and when reconfiguring the serverboard.
  • Page 4: Table Of Contents

    Equipment Installation ..................4-8 Control Panel ....................1-3 Restricted Area ....................4-9 Cooling System ....................1-3 Battery Handling .................... 4-10 Contacting Supermicro ..................1-5 Redundant Power Supplies ................4-12 Chapter 2 Server Installation Backplane Voltage ..................4-13 Overview ......................2-1 Comply with Local and National Electrical Codes ........
  • Page 5 UPER ERVER 6018R-TD User's Manual Jumper Settings .................... 5-19 5-10 Onboard Indicators ..................5-21 5-11 SATA Ports ....................5-22 5-12 Installing Drivers .................... 5-23 SuperDoctor® 5 .................... 5-24 5-13 Onboard Battery .................... 5-25 Chapter 6 Advanced Chassis Setup Static-Sensitive Devices .................. 6-1 Precautions .....................
  • Page 6: Chapter 1 Introduction

    Chapter 1 Introduction Overview The SuperServer 6018R-TD is a 1U server comprised of two main subsystems: the SC813TS-441CBP chassis and the X10DRD-L serverboard. Please refer to our website for information on operating systems that have been certified for use with the system (www.supermicro.com).
  • Page 7: Serverboard Features

    Serverboard Features Server Chassis Features At the heart of the SuperServer 6018R-TD lies the X10DRD-L, a dual processor The following is a general outline of the main features of the SC813TS-441CBP serverboard based on Intel's C612 chipset. Below are the main features of the chassis.
  • Page 8: Contacting Supermicro

    Note: This is a general block diagram. Please see Chapter 5 for details. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 X10DRD-L/LT Email: marketing@supermicro.com (General Information) VCCP0 12v VCCP1 12v VR12.5 VR12.5 support@supermicro.com (Technical Support) 4 PHASE 4 PHASE...
  • Page 9 UPER ERVER 6018R-TD User's Manual Notes...
  • Page 10: Chapter 2 Server Installation

    Chapter 2: Server Installation Chapter 2 Server Installation Overview This chapter provides a quick setup checklist to get your system installed into a rack. Be aware of the warnings and precautions mentioned in this chapter when installing the server into a rack. Unpacking the System You should inspect the box the server was shipped in and note if it was damaged in any way.
  • Page 11: Warnings And Precautions

    Chapter 2: Server Installation UPER ERVER 6018R-TD User's Manual Warnings and Precautions Rack Mounting Considerations Ambient Operating Temperature Rack Precautions If installed in a closed or multi-unit rack assembly, the ambient operating • Ensure that the leveling jacks on the bottom of the rack are fully extended to temperature of the rack environment may be greater than the ambient temperature the floor with the full weight of the rack resting on them.
  • Page 12: Rack Mounting Instructions

    Chapter 2: Server Installation UPER ERVER 6018R-TD User's Manual Rack Mounting Instructions This section provides information on installing the SC813TS-441CBP chassis into a rack unit. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. You should also refer to the installation instructions that came with the rack unit you are using.
  • Page 13 Chapter 2: Server Installation UPER ERVER 6018R-TD User's Manual Secure to the Front of the Rack Secure to the Rear of the Rack Attach the Two Sections of the Outer Rail Together Figure 2-3. Assembling the Outer Rails Installing the Outer Rails to the Rack 1.
  • Page 14: Installing The Chassis Into A Telco Rack

    Chapter 2: Server Installation UPER ERVER 6018R-TD User's Manual Installing the Chassis into a Telco rack To install the chassis into a Telco type rack, use two L-shaped brackets on either side of the chassis (four total). First, determine how far follow the server will extend out the front of the rack.
  • Page 15 UPER ERVER 6018R-TD User's Manual Notes 2-10...
  • Page 16: Overview

    Chapter 3: System Interface Chapter 3 System Interface Overview There are several LEDs on the control panel as well as others on the hard drive carriers to keep you constantly informed of the overall status of the system as well as the activity and health of specific components.
  • Page 17: Control Panel Leds

    Chapter 3: System Interface UPER ERVER 6018R-TD User's Manual Control Panel LEDs The control panel located on the front of the SC813TS-441CBP chassis has five LEDs. These LEDs provide you with critical information related to different parts of the system. This section explains what each LED indicates when illuminated and NIC2 any corrective action you may need to take.
  • Page 18 UPER ERVER 6018R-TD User's Manual Notes...
  • Page 19: Chapter 4 Standardized Warning Statements For Ac Systems

    Only certified technicians should attempt to install or configure components. Read this appendix in its entirety before installing or configuring components in the Supermicro chassis. These warnings may also be found on our web site at http://www.supermicro.com/ about/policies/safety_information.cfm. Warning Definition Warning! This warning symbol means danger.
  • Page 20 Warning Statements for AC Systems UPER ERVER 6018R-TD User's Manual ‫جسذٌة‬ ‫اصابة‬ ً‫تتسبب ف‬ ‫حالة ٌوكي أى‬ ً‫اًك ف‬ ‫خطز‬ ًٌ‫ٌع‬ ‫هذا الزهز‬ !‫تحذٌز‬ Warnung ‫الذوائز‬ ‫بالوخاطز الٌاجوة عي‬ ‫ي على علن‬ ، ‫ك‬ ‫هعذات‬ ‫تعول على أي‬ ‫قبل أى‬ ‫الكهزبائٍة‬...
  • Page 21: Installation Instructions

    Chapter 4: Warning Statements for AC Systems UPER ERVER 6018R-TD User's Manual Installation Instructions Circuit Breaker Warning! Warning! Read the installation instructions before connecting the system to the power source. This product relies on the building's installation for short-circuit (overcurrent) 設置手順書...
  • Page 22: Power Disconnection Warning

    Chapter 4: Warning Statements for AC Systems UPER ERVER 6018R-TD User's Manual Warnung Das System muss von allen Quellen der Energie und vom Netzanschlusskabel ‫في‬ ‫التي تم تثبيتها‬ ‫مه الدوائرالقصيرة‬ ‫الحمايت‬ ‫معداث‬ ‫يعتمد على‬ ‫هذا المنتج‬ getrennt sein, das von den Spg.Versorgungsteilmodulen entfernt wird, bevor es ‫المبنى‬...
  • Page 23: Equipment Installation

    Chapter 4: Warning Statements for AC Systems UPER ERVER 6018R-TD User's Manual Equipment Installation Waarschuwing Deze apparatuur mag alleen worden geïnstalleerd, vervangen of hersteld door geschoold en gekwalificeerd personeel. Warning! Only trained and qualified personnel should be allowed to install, replace, or service Restricted Area this equipment.
  • Page 24: Battery Handling

    Chapter 4: Warning Statements for AC Systems UPER ERVER 6018R-TD User's Manual Warnung ‫אזור עם גישה מוגבלת‬ Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die !‫אזהרה‬ Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. ‫יש להתקין את היחידה באזורים שיש בהם הגבלת גישה. הגישה ניתנת בעזרת‬ Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers.
  • Page 25: Redundant Power Supplies

    Chapter 4: Warning Statements for AC Systems UPER ERVER 6018R-TD User's Manual Redundant Power Supplies ‫امداد الطاقة‬ ‫بوحدات‬ ‫عدة اتصاالت‬ ‫جهاز‬ ‫ال‬ ‫يكون لهذا‬ ‫قد‬ ‫الكهرباء‬ ‫عن‬ ‫وحدة‬ ‫ال‬ ‫لعسل‬ ‫كافة االتصاالت‬ ‫يجب إزالة‬ Warning! This unit might have more than one power supply connection. All connections must 경고! be removed to de-energize the unit.
  • Page 26: Comply With Local And National Electrical Codes

    Chapter 4: Warning Statements for AC Systems UPER ERVER 6018R-TD User's Manual Attention ¡Advertencia! Lorsque le système est en fonctionnement, des tensions électriques circulent sur La instalacion del equipo debe cumplir con las normas de electricidad locales y le fond de panier. Prendre des précautions lors de la maintenance. nacionales.Attention L'équipement doit être installé...
  • Page 27: Hot Swap Fan Warning

    Chapter 4: Warning Statements for AC Systems UPER ERVER 6018R-TD User's Manual 当您从机架移除风扇装置,风扇可能仍在转动。小心不要将手指、螺丝起子和其他 Warnung 物品太靠近风扇 Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des Landes erfolgen. 警告 ¡Advertencia! 當您從機架移除風扇裝置,風扇可能仍在轉動。小心不要將手指、螺絲起子和其他 物品太靠近風扇。 Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales.
  • Page 28: Power Cable And Ac Adapter

    UL ou CSA câbles certifiés qui ont UL ou CSA indiqué sur le code use of UL or CSA -certified cables (that have UL/CSA shown on the code) for any pour tous les autres appareils électriques que les produits désignés par Supermicro other electrical devices than products designated by Supermicro only.
  • Page 29 Elektrisch apparaat en veiligheidsinformatiebladen wet verbiedt het gebruik van UL of CSA gecertificeerde kabels die UL of CSA die op de code voor andere elektrische apparaten dan de producten die door Supermicro alleen. 4-20...
  • Page 30: Chapter 5 Advanced Serverboard Setup

    Chapter 5: Advanced Serverboard Setup Chapter 5 Advanced Serverboard Setup This chapter covers the steps required to install processors and heatsinks to the X10DRD-L serverboard, connect the data and power cables and install add-on cards. All serverboard jumpers and connections are described and a layout and quick reference chart are included in this chapter.
  • Page 31: Processor And Heatsink Installation

    CPU so • that all keys and edges will fit Refer to the Supermicro web site for updates on CPU support. the socket. Installing a CPU 1. There are two levers on the LGA 2011 socket.
  • Page 32: Installing A Passive Cpu Heatsink

    Chapter 5: Advanced Serverboard Setup UPER ERVER 6018R-TD User's Manual Installing a Passive CPU Heatsink 1. Do not apply any thermal grease to the heatsink or the CPU die - the required Gently close amount has already been applied. the load plate. 7.
  • Page 33: Connecting Cables

    Chapter 5: Advanced Serverboard Setup UPER ERVER 6018R-TD User's Manual Connecting Cables Figure 5-2. Front Control Panel Header Pins (JF1) Now that the processors are installed, the next step is to connect the cables to the serverboard. These include the data cables for the peripherals and control panel Power Button Ground and the power cables.
  • Page 34: Installing Memory

    Chapter 5: Advanced Serverboard Setup UPER ERVER 6018R-TD User's Manual Installing Memory Processors and their Corresponding Memory Modules Note: Check the Supermicro web site for recommended memory modules. CPU# Corresponding DIMM Modules CPU 1 CAUTION DIMMA1 DIMMB1 DIMMC1 DIMMD1 Exercise extreme care when installing or removing DIMM modules...
  • Page 35: Adding Pci Expansion Cards

    Chapter 5: Advanced Serverboard Setup UPER ERVER 6018R-TD User's Manual Adding PCI Expansion Cards Serverboard Details Figure 5-5. SUPER X10DRD-L Layout PCI Expansion Slots One RSC-RR1U-E8 riser card is used to support a FHHL (full-height, half-length) LAN2 LAN1 USB0/1 expansion (add-on) card to the system. JUSBRJ45 COM1 AST2400...
  • Page 36: X10Drd-L Quick Reference

    Chapter 5: Advanced Serverboard Setup UPER ERVER 6018R-TD User's Manual Connector Definitions X10DRD-L Quick Reference ATX Power 24-pin Connector Pin Definitions (JPW1) Jumper Description Default Setting Pin# Definition Pin # Definition Power Connectors JBT1 Clear CMOS See Section 5-9 +3.3V +3.3V A 24-pin main ATX power supply connec- C1/JI...
  • Page 37 Chapter 5: Advanced Serverboard Setup UPER ERVER 6018R-TD User's Manual NIC1/NIC2 LED Indicators Power Button NIC1/2 LED Pin Definitions (JF1) The NIC (Network Interface Controller) The Power Button connection is located Power Button Pin# Definition LED connection for LAN port 1 is located on pins 1 and 2 of JF1.
  • Page 38 IPMI, please refer to the IPMI user's the table on the right for pin definitions. +3V_DUAL SERIRQ guide posted on our website @ http:// CLKRUN# (X) www.supermicro.com. LPCPD# LDRQ# (X) PWR SMB Fan Headers Pin Definitions Power SMB (I...
  • Page 39: Super Server 6018R-Td User's Manual

    Chapter 5: Advanced Serverboard Setup UPER ERVER 6018R-TD User's Manual Jumper Settings T-SGPIO 0/1 Headers Serial_Link-SGPIO Explanation of Jumpers Two T-SGPIO (Serial-Link General Pin Definitions Purpose Input/Output) headers are Pin# Definition Definition To modify the operation of the serverboard, included to communicate with the en- jumpers can be used to choose between Connector closure management chip in the system.
  • Page 40: 5-10 Onboard Indicators

    Chapter 5: Advanced Serverboard Setup UPER ERVER 6018R-TD User's Manual 5-10 Onboard Indicators C Bus to PCI-Express Slots Use jumpers JI C1 and JI C2 to connect C for PCI-E slots LAN1/2 LEDs LAN1/2 Link LED (Left) Jumper Settings the System Management Bus (I C) to LED State Jumper Setting...
  • Page 41: 5-11 Sata Ports

    UPER ERVER 6018R-TD User's Manual 5-11 SATA Ports 5-12 Installing Drivers The Supermicro FTP site contains drivers and utilities for your system at ftp://ftp. supermicro.com. Some of these must be installed, such as the chipset driver. SATA Ports After accessing the FTP site, go into the CDR_Images directory and locate the ISO file for your serverboard.
  • Page 42: Superdoctor® 5

    5-13 Onboard Battery SuperDoctor® 5 The Supermicro SuperDoctor 5 is a program that functions in a command-line or Care must be taken to assure that the chassis cover is in place when the system web-based interface in Windows and Linux operating systems. The program moni- is operating to assure proper cooling.
  • Page 43 UPER ERVER 6018R-TD User's Manual Notes 5-26...
  • Page 44: Chapter 6 Advanced Chassis Setup

    Chapter 6: Advanced Chassis Setup Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform main- tenance on the SC813TS-441CBP chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered. If some steps are unnecessary, skip ahead to the next step.
  • Page 45: Control Panel

    Two 10-cm blower fans and one 4-cm fan provide all the cooling needed for the Figure 6-1. Chassis: Front and Rear Views SuperServer 6018R-TD. It is very important that the chassis top cover is properly installed and making a good seal in order for the cooling air to circulate properly through the chassis and cool the components.
  • Page 46: Drive Bay Installation/Removal

    Chapter 6: Advanced Chassis Setup UPER ERVER 6018R-TD Manual Drive Bay Installation/Removal Removing the Front Bezel Figure 6-2. Accessing the Inside of the System If your system has the optional front bezel attached to the chassis, you must first remove it to gain access to the drive bays. 1.
  • Page 47: Sata Drive Installation

    Also, regardless of how many drives are installed, all four drive carriers must remain in the chassis to maintain proper airflow. Warning: Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers. For information on recommended HDDs, visit the Supermicro website at http://www.supermicro.com/products/nfo/files/storage/SAS-1-Com-...
  • Page 48: Dvd Drive Installation

    The top cover of the chassis must be opened to gain full access to the DVD drive The SuperServer 6018R-TD has a single 440-480 watt power supply, which is bay. The 6018R-TD accomodates only slim DVD drives and side mounting brackets auto-switching capable.
  • Page 49 UPER ERVER 6018R-TD Manual Figure 6-7. Removing/Replacing the Power Supply 6-10...
  • Page 50: Chapter 7 Bios

    When an option is selected in the left frame, it is highlighted in white. Often a text message will accompany it. Note: The AMI BIOS has default text messages built in. Supermicro retains the option to include, omit, or change any of these text messages.
  • Page 51: How To Start The Setup Utility

    Flashing the wrong BIOS can cause irreparable damage to the system. In no event as 17:30:00. shall Supermicro be liable for direct, indirect, special, incidental, or consequential dam- ages arising from a BIOS update. If you have to update the BIOS, do not shut down Supermicro X10DRD-iT or reset the system while the BIOS is updating.
  • Page 52: Advanced Setup Configurations

    UPER ERVER 6018R-TD User's Manual Chapter 7: BIOS Advanced Setup Configurations Wait For 'F1' If Error Select Enabled to force the system to wait until the <F1> key is pressed if an error Use the arrow keys to select the Advanced tab and press <Enter> to access the occurs.
  • Page 53: Cpu Configuration

    UPER ERVER 6018R-TD User's Manual Chapter 7: BIOS CPU Configuration Execute Disable Bit (Available if supported by the OS & the CPU)  Select Enable to enable the Execute-Disable Bit technology which will allow the This submenu displays the information of the CPU as detected by the BIOS. It also processor to designate areas in the system memory where an application code allows the user to configuration CPU settings.
  • Page 54: Advanced Power Management Configuration

    UPER ERVER 6018R-TD User's Manual Chapter 7: BIOS  CPU P State Control (Available when Power Technology Intel Virtualization Technology (Available when supported by the CPU) is set to Custom) Select Enable for Intel Virtualization Technology support, which will allow one platform to run multiple operating systems and applications in independent parti- EIST (P-States) (Available when Power Technology is set to Custom) tions, creating multiple "virtual"...
  • Page 55: Ioat Configuration

    UPER ERVER 6018R-TD User's Manual Chapter 7: BIOS Enhanced Halt State (C1E) CPU1 SLOT4 PCI-E 3.0 x8 Select Enable to use Enhanced Halt-State technology, which will significantly Use this feature to set the PCI-E bus speed for the slot specified above. The reduce CPU power consumption by reducing CPU clock cycle and voltage during options are Gen (Generation) 1 (2.5 GT/s), Gen (Generation) 2 (5 GT/s), and a halt-state.
  • Page 56: Memory Configuration

    UPER ERVER 6018R-TD User's Manual Chapter 7: BIOS Interrupt Remapping Isoc Mode Select Enable for Interrupt Remapping support to enhance system performance. Select Enable to enable Isochronous support to meet QoS (Quality of Service) The options are Enable and Disable. requirements.
  • Page 57 UPER ERVER 6018R-TD User's Manual Chapter 7: BIOS • P1-DIMMA1 Patrol Scrub Interval This feature allows you to decide how many hours the system should wait before • P1-DIMMB1 the next complete patrol scrub is performed. Use the keyboard to enter a value from 0 to 24.
  • Page 58 UPER ERVER 6018R-TD User's Manual Chapter 7: BIOS SATA Configuration EHCI1  Select Enabled to enable EHCI (Enhanced Host Controller Interface) support on When this submenu is selected, the AMI BIOS automatically detects the presence USB 2.0 connector #1. (At least one USB 2.0 connector should be enabled for EHCI of the SATA devices that are supported by the Intel PCH chip and displays the support.) The options are Disabled and Enabled.
  • Page 59 UPER ERVER 6018R-TD User's Manual Chapter 7: BIOS Port 0-5 SATA Device Type Port 0-5 Hot Plug Use this item to specify if the SATA port specified by the user should be con- Select Enabled to enable hot-plugging support for a port specified by the user, nected to a solid state drive or a hard disk drive.
  • Page 60 UPER ERVER 6018R-TD User's Manual Chapter 7: BIOS sSATA Port 0-3 Spin Up Device sSATA Port 0-3 Hot Plug On an edge detect from 0 to 1, set this item to allow the PCH to start a COMRE- Select Enabled to support hot-plugging on the port specified by the user, which SET initialization to the device.
  • Page 61 UPER ERVER 6018R-TD User's Manual Chapter 7: BIOS Above 4G Decoding (Available if the system supports 64-bit PCI decoding) Onboard LAN1 Option ROM/Onboard LAN2 Option ROM Select Enabled to decode a PCI device that supports 64-bit in the space above 4G Use this option to select the type of device installed in LAN Port1 or LAN Port2 Address.
  • Page 62 UPER ERVER 6018R-TD User's Manual Chapter 7: BIOS The options for Serial Port 1 are Auto, (IO=3F8h; IRQ=4), (IO=3F8h; IRQ=3, 4, 5, Parity 6, 7, 9, 10, 11, 12), (IO=2F8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12), (IO=3E8h; IRQ=3, A parity bit can be sent along with regular data bits to detect data transmission 4, 5, 6, 7, 9, 10, 11, 12), and (IO=2E8h;...
  • Page 63 UPER ERVER 6018R-TD User's Manual Chapter 7: BIOS in transmission. Select Mark to add a mark as a parity bit to be sent along with Redirection After BIOS Post the data bits. Select Space to add a Space as a parity bit to be sent with your Use this feature to enable or disable legacy Console Redirection after BIOS data bits.
  • Page 64 The options are Enabled and Disabled. Flow Control Note: Refer to the Supermicro TPM user's guide for more details on how Use this item to set the flow control for Console Redirection to prevent data to install and set up the TPM in the BIOS.
  • Page 65: Event Logs

    UPER ERVER 6018R-TD User's Manual Chapter 7: BIOS Event Logs TPM State Select Enabled to use TPM (Trusted Platform Module) settings to enhance system Use this feature to configure event log settings. data security. Please reboot your system for any change on the TPM state to take effect.
  • Page 66: Ipmi

    UPER ERVER 6018R-TD User's Manual Chapter 7: BIOS SMBIOS Event Log Standard Settings IPMI Log System Boot Event Use this feature to configure Intelligent Platform Management Interface (IPMI) settings. Select Enabled to log system boot events. The options are Enabled and Disabled. MECI (Multiple Event Count Increment) Enter the increment value for the multiple event counter.
  • Page 67: Security Settings

    UPER ERVER 6018R-TD User's Manual Chapter 7: BIOS Security Settings When SEL is Full This feature allows the user to determine what the BIOS should do when the sys- This menu allows the user to configure the following security settings for the tem event log is full.
  • Page 68 UPER ERVER 6018R-TD User's Manual Chapter 7: BIOS Secure Boot Menu  Set New KEK (Key Exchange Key)  Select <Yes> to confirm that a new KEK will be set in the NVRAM (Non-Volatile System Mode RAM). Secure Boot  Append KEK (Key Exchange Key) Select <Yes>...
  • Page 69: Boot Settings

    UPER ERVER 6018R-TD User's Manual Chapter 7: BIOS Boot Settings  Set New DBX Select <Yes> to confirm that the new DBX files will be downloaded to the Non- Use this feature to configure boot settings: Volatile RAM (NVRAM).  Append DBX (DataBase Timer) Select <Yes>...
  • Page 70 UPER ERVER 6018R-TD User's Manual Chapter 7: BIOS • • Dual Boot Order #6 Legacy Boot Order #1 • Dual Boot Order #7  UEFI Application Boot Priorities • • UEFI Boot Order #1 Dual Boot Order #8 • Dual Boot Order #9 •...
  • Page 71: Save & Exit

    UPER ERVER 6018R-TD User's Manual Chapter 7: BIOS Save & Exit Save As User Defaults Select this option and press <Enter> to save any changes to the BIOS setup for Select the Save & Exit tab from the BIOS setup screen to configure the settings future use.
  • Page 72 UPER ERVER 6018R-TD User's Manual Notes 7-44...
  • Page 73: Appendix A Bios Error Beep Codes

    Appendix A: BIOS Error Beep Codes Appendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed upon each system boot, errors may occur. Non-fatal errors are those which, in most cases, allow the system to continue to boot.
  • Page 74 UPER ERVER 6018R-TD User's Manual Notes...
  • Page 75: Appendix B System Specifications

    Appendix B: System Specifications Appendix B System Specifications Processors Dual Intel Xeon E5-2600 v3/v4 Series processors in LGA2011 (Socket R3) sockets Note: Please refer to our web site for a complete listing of supported processors. Chipset Intel PCH C612 Memory Capacity Eight DIMM sockets that can support up to 1 TB of ECC LRDIMM (Load Reduced DIMMs) or 512 GB of ECC RDIMM (Registered DIMMs) DDR4- 2400/2133/1866/1600 memory...
  • Page 76 Disclaimer (continued from front) EN 60950/IEC 60950-Compliant, UL Listed (USA), CUL Listed (Canada), TUV The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency com-...
  • Page 77 UPER ERVER 6018R-TD User's Manual Notes...

Table of Contents