Page 2
Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product.
About This Manual This manual is written for professional system integrators and PC technicians. It pro- vides information for the installation and use of the SuperServer 6015B-3R. Instal- lation and maintainance should be performed by experienced technicians only. The SuperServer 6015B-3R is a high-end server based on the SC815TQ-R650 1U rackmount chassis and the Super X7DBR-3, a dual processor serverboard that sup- ®...
Page 4
UPER ERVER 6015B-3R User's Manual Chapter 4: System Safety You should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the SuperServer 6015B-3R. Chapter 5: Advanced Serverboard Setup Chapter 5 provides detailed information on the X7DBR-3 serverboard, including the locations and functions of connections, headers and jumpers.
UPER ERVER 6015B-3R User's Manual Table of Contents Preface About This Manual ... iii Manual Organization ... iii Chapter 1: Introduction Overview ... 1-1 Serverboard Features ... 1-2 Server Chassis Features ... 1-3 Contacting Super Micro ... 1-6 Chapter 2: Server Installation Overview ...
Page 7
Chapter 4: System Safety Electrical Safety Precautions ... 4-1 General Safety Precautions ... 4-2 ESD Precautions ... 4-3 Operating Precautions ... 4-4 Chapter 5: Advanced Serverboard Setup Handling the Serverboard ... 5-1 Processor and Heatsink Installation ... 5-2 Connecting Cables ... 5-5 Connecting Data Cables ...
Overview The SuperServer 6015B-3R is a high-end server comprised of two main subsys- tems: the SC815TQ-R650 1U server chassis and the X7DBR-3 dual processor serverboard. Please refer to our web site for information on operating systems that have been certifi ed for use with the SuperServer 6015B-3R (www.supermicro.
ERVER 6015B-3R User's Manual Serverboard Features At the heart of the SuperServer 6015B-3R lies the X7DBR-3, a dual processor serverboard based on Intel's 5000P chipset. Below are the main features of the X7DBR-3 (see Figure 1-1 for a block diagram of the chipset).
BIOS rescue. Server Chassis Features The SuperServer 6015B-3R is a high-end, scaleable server platform built upon the SC815TQ-R650 1U server chassis. The following is a general outline of the main features of the SC815TQ-R650 chassis.
Page 14
UPER ERVER 6015B-3R User's Manual Front Control Panel The SC815TQ-650's control panel provides you with system monitoring and control. LEDs indicate system power, HDD activity, network activity (2) and overheat/fan failure. A main power button and system reset button is also included.
Page 15
Figure 1-1. Intel 5000P Chipset: System Block Diagram Note: This is a general block diagram. Please see Chapter 5 for details. PROCESSOR#2 ISL6307 667/1067/ 1333 MT/S PCI-Ex8 PORT #4,5 PCI-Ex8 PORT #6,7 PORT PORT PCI-Ex8 #1,2 PCI-X100 SCSI PCIX PCI-33 ES1000 CONN PCI33MMZ...
If the server itself shows damage you should fi le a damage claim with the carrier who delivered it. Decide on a suitable location for the rack unit that will hold the 6015B-3R. It should be situated in a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical noise and electromagnetic fi...
UPER ERVER 6015B-3R User's Manual Choosing a Setup Location - Leave enough clearance in front of the rack to enable you to open the front door completely (~25 inches). - Leave approximately 30 inches of clearance in the back of the rack to allow for suffi...
Chapter 2: Server Installation Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi-unit rack assembly, the ambient operating tempera- ture of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient tempera- ture (Tmra).
ERVER 6015B-3R User's Manual Installing the System into a Rack This section provides information on installing the 6015B-3R into a rack unit with the rack rails provided. If the system has already been mounted into a rack, you can skip ahead to Sections 2-5 and 2-6. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly.
Chapter 2: Server Installation Installing the Outer Rails Begin by measuring the distance from the front rail to the rear rail of the rack. Attach a short bracket to the front side of the right outer rail and a long bracket to the rear side of the right outer rail.
UPER ERVER 6015B-3R User's Manual Installing the Server into the Rack You should now have rails attached to both the chassis and the rack unit. The next step is to install the server into the rack. Do this by lining up the rear of the chas- sis rails with the front of the rack rails.
Chapter 2: Server Installation Installing the Server into a Telco Rack To install the 6015B-3R into a Telco type rack, use two L-shaped brackets on either side of the chassis (four total). First, determine how far follow the server will extend out the front of the rack.
UPER ERVER 6015B-3R User's Manual Checking the Serverboard Setup After you install the 6015B-3R in the rack, you will need to open the top cover to make sure the serverboard is properly installed and all the connections have been made.
Page 25
Chapter 2: Server Installation Figure 2-5. Accessing the Inside of the System...
UPER ERVER 6015B-3R User's Manual Checking the Drive Bay Setup Next, you should check to make sure the peripheral drives and the SAS drives and SAS backplane have been properly installed and all connections have been made. 1. Accessing the drive bays All drives are accessable from the front of the server.
System Interface Overview There are several LEDs on the control panel as well as others on the SAS drive carriers to keep you constantly informed of the overall status of the system as well as the activity and health of specifi c components. There are also two buttons on the chassis control panel and an on/off switch on the power supply.
NIC2: Indicates network activity on GLAN2 when fl ashing . NIC1: Indicates network activity on GLAN1 when fl ashing. HDD: Indicates IDE channel activity. On the SuperServer 6015B-3R this light indicates SAS and/or DVD-ROM drive activity when fl ashing.
Power: Indicates power is being supplied to the system's power supply units. This LED should normally be illuminated when the system is operating. Drive Carrier LEDs SAS Drives Each SAS drive carrier has two LEDs: Green: When illuminated, the green LED on the front of the SAS drive carrier indicates drive activity.
Electrical Safety Precautions Basic electrical safety precautions should be followed to protect yourself from harm and the SuperServer 6015B-3R from damage: Be aware of the locations of the power on/off switch on the chassis as well as the room's emergency power-off switch, disconnection switch or electrical outlet.
General Safety Precautions Follow these rules to ensure general safety: Keep the area around the SuperServer 6015B-3R clean and free of clutter. The SuperServer 6015B-3R weighs approximately 41 lbs (18.6 kg) when fully loaded. When lifting the system, two people at either end should lift slowly with their feet spread out to distribute the weight.
After accessing the inside of the system, close the system back up and secure it to the rack unit with the retention screws after ensuring that all connections have been made. ESD Precautions Electrostatic discharge (ESD) is generated by two objects with different electrical charges coming into contact with each other.
Operating Precautions Care must be taken to assure that the chassis cover is in place when the 6015B-3R is operating to ensure proper cooling. Out of warranty damage to the 6015B-3R system can occur if this practice is not strictly followed.
Advanced Serverboard Setup This chapter covers the steps required to install processors and heatsinks to the X7DBR-3 serverboard, connect the data and power cables and install add-on cards. All serverboard jumpers and connections are described and a layout and quick reference chart are included in this chapter. Remember to close the chas- sis completely when you have fi...
UPER ERVER 6015B-3R User's Manual Processor and Heatsink Installation When handling the processor, avoid placing direct pressure on the label area of the fan. Also, do not place the serverboard on a conductive surface, which can damage the BIOS battery and prevent the system from booting up.
Page 37
3. Use your thumb and your index fi nger to hold the CPU at opposite sides. 4. Align pin1 of the CPU (the cor- ner marked with a triangle) with the notched corner of the CPU socket. 5. Find the corner of the CPU that has a semi-circle cutout below a gold dot (CPU key).
Page 38
UPER ERVER 6015B-3R User's Manual Installing the Heatsink 1. Do not apply any thermal grease to the heatsink or the CPU die; the required amount has already been applied. 2. Place the heatsink on top of the CPU so that the four mounting holes are aligned with those on the (preinstalled) heatsink retention mechanism.
Connecting Cables Now that the processors are installed, the next step is to connect the cables to the serverboard. These include the data (ribbon) cables for the peripherals and control panel and the power cables. Connecting Data Cables The ribbon cables used to transfer data from the peripheral devices have been carefully routed in preconfi...
UPER ERVER 6015B-3R User's Manual Connecting the Control Panel JF1 contains header pins for various front control panel connectors. See Figure 5-1 for the pin locations of the various front control panel buttons and LED indi- cators. Please note that even and odd numbered pins are on opposite sides of each header.
I/O Ports The I/O ports are color coded in conformance with the PC 99 specifi cation. See Figure 5-2 below for the colors and locations of the various I/O ports. Figure 5-2. Rear Panel I/O Ports Note: the external SAS port is included on the 6015B-3 only. Installing Memory Note: Check the Super Micro web site for recommended memory modules.
Page 42
UPER ERVER 6015B-3R User's Manual Memory Support The X7DBR-3 supports up to 32 GB of ECC FBD (Fully Buffered DIMM) DDR2-667 or DDR2-533 SDRAM. The memory is an interleaved confi guration, which requires modules of the same size and speed to be installed in pairs. You should not mix DIMMs of different sizes and speeds.
Chapter 5: Advanced Serverboard Setup Adding PCI Cards 1. PCI Expansion Slots The X7DBR-3 has two Universal PCI slots, each of which support either one PCI- Express x8 card or one PCI-X 133/100 MHz card. (On the X7DBR-3, slot #7 is a 100 MHz PCI-X slot, on the X7DBR-3 slot #7 is a 133 MHz PCI-CX slot.) The SC815TQ- R650 chassis can accommodate one standard size (full height full length) and one low profi...
UPER ERVER 6015B-3R User's Manual Connector Defi nitions ATX Power Connector The primary ATX power supply con- nector meets the SSI (Superset ATX) 20-pin specifi cation. Make sure that the orientation of the connector is correct. See the table on the right for pin defi...
HDD LED The HDD (IDE Hard Disk Drive) LED connection is located on pins 13 and 14 of JF1. Attach the IDE hard drive LED cable to display disk activity. Refer to the table on the right for pin defi nitions. NIC1 LED The NIC1 (Network Interface Control- ler) LED connection is located on pins...
UPER ERVER 6015B-3R User's Manual Power Fail LED The Power Fail LED connection is located on pins 5 and 6 of JF1. Re- fer to the table on the right for pin defi nitions. Reset Button The Reset Button connection is lo- cated on pins 3 and 4 of JF1.
Serial Ports The COM1 serial port is located on the IO backplane. COM2 is a header on the serverboard (see serverboard layout for location). See the table on the right for pin defi nitions. Power Supply Fail Header Connect a cable from your power sup- ply to the Power Fail header to provide you with warning of a power supply failure.
UPER ERVER 6015B-3R User's Manual Universal Serial Bus Headers Four additional USB headers (at JUSB2 and JUSB3) are included on the serverboard. These may be used for front side access. A USB cable (not included) is needed for the con- nection.
Wake-On-LAN The Wake-On-LAN header is desig- nated JWOL. See the table on the right for pin defi nitions. You must enable the LAN Wake-Up setting in BIOS to use this feature. You must also have a LAN card with a Wake- on-LAN connector and cable.
UPER ERVER 6015B-3R User's Manual JLAN1/2 (Ethernet Ports) Two Ethernet ports (designated JLAN1 and JLAN2) are located beside the VGA port on the I/O backplane. These ports accept RJ45 type cables. Alarm Reset (JAR) The system will notify you in the event of a power supply failure.
Jumper Settings Explanation of Jumpers To modi f y the operat ion of the serverboard, jumpers can be used to choose between optional settings. Jumpers create shorts between two pins to change the function of the connector. Pin 1 is identifi ed with a square solder pad on the printed circuit board.
UPER ERVER 6015B-3R User's Manual 3rd Power Supply Fail Detect Enable/Disable The system can notify you in the event of a power supply failure. This feature assumes that three power supply units are installed in the chassis with one act- ing as a backup.
SAS Controller Enable JPS1 enables or disables the Adapt- ec 9140W SAS controller on the serverboard. See the table on the right for jumper settings. The default setting is enabled. Compact Flash Master/ Slave The JCF1 jumper allows you to as- sign either master or slave status to a compact fl...
UPER ERVER 6015B-3R User's Manual 5-11 Floppy, IDE, SATA and SAS Drive Connections Note the following when connecting the fl oppy and hard disk drive cables: • The fl oppy disk drive cable has seven twisted wires. • A red mark on a wire typically designates the location of pin 1.
IDE Connectors There are no jumpers to con- fi gure the onboard IDE1 and IDE2 connectors. See the table on the right for pin defi ni- tions. SATA Ports See the table on the right for pin defi nitions for the onboard SATA ports.
UPER ERVER 6015B-3R User's Manual SAS Ports There are eight Serial Attached SCSI ports on the serverboard (SAS0~3 and SAS4~7). See the tables on the right for pin defi nitions. SAS Ports Pin Defi nitions (SAS0~3, SAS4~7) Pin# Defi nition Pin # Defi...
Advanced Chassis Setup This chapter covers the steps required to install components and perform mainte- nance on the SC815TQ-R650 chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered. If some steps are unnecessary, skip ahead to the next step. Tools Required The only tool you will need to install components and perform maintenance is a Philips screwdriver.
UPER ERVER 6015B-3R User's Manual Figure 6-1. Chassis: Front and Rear Views Slim DVD-ROM Drive Slim Floppy Drive (optional) Power Supply Module USB Ports Mouse/Keyboard COM1 Port Control Panel The control panel (located on the front of the chassis) must be connected to the JF1 connector on the serverboard to provide you with system status indications.
System Fans Four 40-mm heavy duty counter-rotating fans provide the cooling for the SuperServer 6015B-3R. Each fan unit is actually made up of two fans joined back-to-back, which rotate in opposite directions. This counter-rotating action generates exceptional airfl ow and works to dampen vibration levels. It is very important that the chassis top cover is properly installed and making a good seal in order for the cooling air to circulate properly through the chassis and cool the components.
UPER ERVER 6015B-3R User's Manual Figure 6-2. System Cooling Fans Drive Bay Installation/Removal Removing the Front Bezel If your system has a front bezel (optional) attached to the chassis, you must fi rst remove it to gain access to the drive bays. To remove the bezel, fi rst unlock the front of the chassis then press the release knob (see Figure 6-3).
DVD-ROM/Floppy Disk Drives: For installing/removing a DVD-ROM or fl oppy disk drive, you will need to gain access to the inside of the 6015B-3R by removing the top cover of the chassis. Proceed to the "DVD-ROM and Floppy Drive Installation"...
UPER ERVER 6015B-3R User's Manual SAS Drive Installation 1. Mounting a SAS drive in a drive carrier The SAS drives are mounted in drive carriers to simplify their installation and re- moval from the chassis. These carriers also help promote proper airfl ow for the drive bays.
Page 65
Chapter 6: Advanced Chassis Setup 2. Installing/removing hot-swap SAS drives The SAS drive carriers are all easily accessible at the front of the chassis. These hard drives are hot-pluggable, meaning they can be removed and installed without powering down the system. To remove a carrier, push the release button located beside the drive LEDs.
DVD-ROM and Floppy Drive Installation The top cover of the chassis must be opened to gain full access to the DVD-ROM and fl oppy drive bays. The 6015B-3R accomodates only slim-line DVD-ROM drives. Side mounting brackets are needed to mount a slim-line DVD-ROM drive in the 6015B-3R server.
Chapter 6: Advanced Chassis Setup Power Supply The SuperServer 6015B-3R has a 650 watt redundant power supply confi guration consisting of two hot-swappable power modules. The power supply modules have an auto-switching capability, which enables them to automatically sense and operate with a 100V - 240V input voltage.
Page 68
UPER ERVER 6015B-3R User's Manual Figure 6-6. Removing/Replacing the Power Supply 6-10...
Note: Due to periodic changes to the BIOS, some settings may have been added or deleted and might not yet be recorded in this manual. Please refer to the Manual Download area of the Super Micro web site <http://www.supermicro.com> for any changes to the BIOS that may not be refl ected in this manual.
UPER ERVER 6015B-3R User's Manual Running Setup Default settings are in bold text unless otherwise noted. The BIOS setup options described in this section are selected by choosing the ap- propriate text from the main BIOS Setup screen. All displayed text is described in this section, although the screen display is often all you need to understand how to set the options (see next page).
Chapter 7: BIOS Main BIOS Setup Menu Main Setup Features System Time To set the system date and time, key in the correct information in the appropriate fi elds. Then press the <Enter> key to save the data. System Date Using the arrow keys, highlight the month, day and year fi...
Page 72
UPER ERVER 6015B-3R User's Manual IDE Channel 0 Master/Slave, IDE Channel 1 Master/Slave, SATA Port2 and SATA Port3 These settings allow the user to set the parameters of IDE Channel 0 Master/ Slave, IDE Channel 1 Master/Slave, IDE Channel 2 Master, IDE Channel 3 Master slots.
Page 73
CHS Format The following items will be displayed by the BIOS: TYPE: This item displays the type of IDE or SATA Device. Cylinders: This item indicates the status of Cylinders. Headers: This item indicates the number of headers. Sectors: This item displays the number of sectors. Maximum Capacity: This item displays the maximum storage capacity of the system.
Page 74
UPER ERVER 6015B-3R User's Manual Parallel ATA This setting allows the user to enable or disable the function of Parallel ATA. The options are Channel 0 and Channel 1. Serial ATA This setting allows the user to enable or disable the function of Serial ATA. The options are Disabled and Enabled.
Chapter 7: BIOS System Memory This display informs you how much system memory is recognized as being present in the system. Extended Memory This display informs you how much extended memory is recognized as being present in the system. Advanced Setup Choose Advanced from the Phoenix BIOS Setup Utility main menu with the arrow keys.
Page 76
UPER ERVER 6015B-3R User's Manual Boot Features Access the submenu to make changes to the following settings. QuickBoot Mode If enabled, this feature will speed up the POST (Power On Self Test) routine by skipping certain tests after the computer is turned on. The settings are Enabled and Disabled.
Page 77
Chapter 7: BIOS Memory Cache Cache System BIOS Area This setting allows you to designate a reserve area in the system memory to be used as a System BIOS buffer to allow the BIOS write (cache) its data into this reserved memory area.
Page 78
UPER ERVER 6015B-3R User's Manual or written into the L1, L2, L3 cache inside the CPU to speed up CPU operations. Select "Uncached" to disable this function. Select "Write Through" to allow data to be cached into the buffer and written into the system memory at the same time.
Page 79
Slot#6 PCI-X 133MHz, Slot E1 x8, Slot E2 x4 and Slot E3 x8 Access the submenu for each of the settings above to make changes to the following: Option ROM Scan When enabled, this setting will initialize the device expansion ROM. The options are Enabled and Disabled.
Page 80
UPER ERVER 6015B-3R User's Manual Memory Branch Mode This option determines how the two memory branches operate. System address space can either be interleaved between the two branches or Sequential from one branch to another. Mirror mode allows data correction by maintaining two copies of data in two branches.
Page 81
Chapter 7: BIOS Advanced Processor Options Access the submenu to make changes to the following settings. CPU Speed This is a display that indicates the speed of the installed processor. Frequency Ratio (Available when supported by the CPU.) The feature allows the user to set the internal frequency multiplier for the CPU. The options are: Default, x12, x13, x14, x15, x16, x17 and x18.
Page 82
UPER ERVER 6015B-3R User's Manual Adjacent Cache Line Prefetch (Available when supported by the CPU.) The CPU fetches the cache line for 64 bytes if this option is set to Disabled. The CPU fetches both cache lines for 128 bytes as comprised if Enabled. The options are Disabled and Enabled.
Page 83
Chapter 7: BIOS Interrupt This setting allows you to select the IRQ (interrupt request) for serial port A. The options are IRQ3 and IRQ4. Serial Port B This setting allows you to assign control of serial port B. The options are Enabled (user defi...
Page 84
UPER ERVER 6015B-3R User's Manual DMI Event Logging Access the submenu to make changes to the following settings. Event Log Validity This is a display to inform you of the event log validity. It is not a setting. Event Log Capacity This is a display to inform you of the event log capacity.
Page 85
Chapter 7: BIOS Console Redirection Access the submenu to make changes to the following settings. COM Port Address This item allows you to specify to redirect the console to Onboard COM A or Onboard COM B. This setting can also be Disabled. BAUD Rate This item allows you to select the BAUD rate for console redirection.
UPER ERVER 6015B-3R User's Manual Hardware Monitor Logic Note: The Phoenix BIOS will automatically detect the type of CPU(s) and hardware monitoring chip used on the motherboard and will display the Hardware Monitoring Screen accordingly. Your Hardware Monitoring Screen may look like the one shown on this page, on p.
Page 87
Chapter 7: BIOS Hardware Monitor Logic CPU Temperature Threshold (See note on page 7-18.) This option allows the user to set a CPU temperature threshold that will activate the alarm system when the CPU temperature reaches this pre-set temperature threshold. The options are 75 C, 80 C, 85 C, and 90...
Page 88
UPER ERVER 6015B-3R User's Manual Hardware Monitor Logic (See note on page 7-18.) CPU Temperature Threshold This option allows the user to set a CPU temperature threshold that will activate the alarm system when the CPU temperature reaches this pre-set temperature threshold.
Page 89
IPMI (This option available only when an IPMI card is installed in the system.) IPMI Specifi cation Version: Firmware Version: This item displays the current Firmware Version. System Event Logging Select Enabled to enable IPMI Event Logging. When this function is set to Disabled, the system will continue to log events received via system interface.
Page 90
UPER ERVER 6015B-3R User's Manual OS Boot Watch Dog Set to Enabled to enable OS Boot Watch Dog. The options are Enabled and Disabled. Timer for Loading OS (Minutes) This feature allows the user to set the time value (in minutes) for the previous item: OS Boot Watch Dog by keying-in a desired number in the blank.
Page 91
Chapter 7: BIOS Realtime Sensor Data This feature display information from motherboard sensors, such as temperatures, fan speeds and voltages of various components. 7-23...
UPER ERVER 6015B-3R User's Manual Security Choose Security from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should see the following display. Security setting options are displayed by highlighting the setting using the arrow keys and pressing <Enter>. All Security BIOS settings are described in this section.
Password on Boot This setting allows you to require a password to be entered when the system boots up. The options are Enabled (password required) and Disabled (password not required). Boot Choose Boot from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should see the following display.
UPER ERVER 6015B-3R User's Manual Exit Choose Exit from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should see the following display. All Exit BIOS settings are described in this section. Exit Saving Changes Highlight this item and hit <Enter> to save any changes you made and to exit the BIOS Setup utility.
Appendix A: BIOS POST Messages Appendix A BIOS POST Messages During the Power-On Self-Test (POST), the BIOS will check for problems. If a prob- lem is found, the BIOS will activate an alarm or display a message. The following is a list of such BIOS messages.
Page 96
UPER ERVER 6015B-3R User's Manual System CMOS checksum bad - Default confi guration used System CMOS has been corrupted or modifi ed incorrectly, perhaps by an application program that changes data stored in CMOS. The BIOS installed Default Setup Values.
Page 97
Appendix A: BIOS POST Messages System cache error - Cache disabled RAM cache failed and BIOS disabled the cache. On older boards, check the cache jumpers. You may have to replace the cache. See your dealer. A disabled cache slows system performance considerably.
Page 98
UPER ERVER 6015B-3R User's Manual Fixed Disk n Fixed disk n (0-3) identifi ed. Invalid System Confi guration Data Problem with NVRAM (CMOS) data. I/O device IRQ confl ict I/O device IRQ confl ict error. PS/2 Mouse Boot Summary Screen: PS/2 Mouse installed.
Page 99
Appendix A: BIOS POST Messages Press <F1> to resume, <F2> to Setup, <F3> for previous Displayed after any recoverable error message. Press <F1> to start the boot process or <F2> to enter Setup and change the settings. Press <F3> to display the previous screen (usually an initialization error of an Option ROM, i.e., an add-on card).
Appendix B BIOS POST Codes This section lists the POST (Power On Self Test) codes for the PhoenixBIOS. POST codes are divided into two categories: recoverable and terminal. Recoverable POST Errors When a recoverable type of error occurs during POST, the BIOS will display an POST code that describes the problem.
Page 102
UPER ERVER 6015B-3R User's Manual POST Code Description 8254 timer initialization 8237 DMA controller initialization Reset Programmable Interrupt Controller 1-3-1-1 Test DRAM refresh 1-3-1-3 Test 8742 Keyboard Controller Set ES segment register to 4 GB Auto size DRAM Initialize POST Memory Manager...
Page 103
POST Code Description Test RAM between 512 and 640 kB Test extended memory Test extended memory address lines Jump to UserPatch1 Confi gure advanced cache registers Initialize Multi Processor APIC Enable external and CPU caches Setup System Management Mode (SMM) area Display external L2 cache size Load custom defaults (optional) Display shadow-area message...
Page 104
UPER ERVER 6015B-3R User's Manual POST Code Description Check for SMART Drive (optional) Set up Power Management Initialize security engine (optional) Enable hardware interrupts Determine number of ATA and SCSI drives Set time of day Check key lock Initialize typematic rate Erase <ESC>...
Page 105
POST Code Description Unknown interrupt Check Intel Branding string Alert Standard Format initialization Late init for IPMI Log error if micro-code not updated properly The following are for boot block in Flash ROM POST Code Description Initialize the chipset Initialize the bridge Initialize the CPU Initialize system timer Initialize system I/O...
Appendix C: Software Installation Appendix C Software Installation C-1 Installing Additional Drivers After you've installed the Windows Operating System, a screen as shown below will appear. You are ready to install software programs and drivers that have not yet been installed. To install these software programs and drivers, click the icons to the right of these items.
Page 108
UPER ERVER 6015B-3R User's Manual Confi guring Supero Doctor III The Supero Doctor III program is a Web based management tool that supports remote management capability. It includes Remote and Local Management tools. The local management is called SD III Client. The Supero Doctor III program in- cluded on the CDROM that came with your motherboard allows you to monitor the environment and operations of your system.
Page 109
Figure C-2. Supero Doctor Screen: Remote Control Note: SD III Software Revision 1.0 can be downloaded from our Web site at: ftp:// ftp.supermicro.com/utility/Supero_Doctor_III/. You can also download SDIII User's Guide at: http://www.supermicro.com/PRODUCT/Manuals/SDIII/UserGuide.pdf. For Linux, we will still recommend that you use Supero Doctor II.
Appendix D: SAS RAID Setup Appendix D SAS RAID Setup D-1 Enabling SAS RAID After the hardware is set up, you should install the operating system and the SAS RAID drivers, you may wish to confi gure a RAID array with your SAS drives. This section gives an outline of the Adaptec SAS Utility program and instructions for creating a RAID array on your system.
UPER ERVER 6015B-3R User's Manual SAS Controller Utility You are now in the SAS Controller Utility program. In this utility, you can create, confi gure, manage and delete RAID arrays. Navigating through the utility is done by using the arrow keys on your keyboard to move between fi elds. The <Enter> key is used to select a highlighted fi...
Page 113
Appendix D: SAS RAID Setup Figure D-3. Array Confi guration Utility Screen Figure D-4. Creating an Array...
UPER ERVER 6015B-3R User's Manual 4. Once all drives have been selected for the RAID array, you will be prompted to select the RAID properties, including the type of RAID to be used, label, array size and stripe size (see Figure D-5). When the properties have been defi ned, highlight Done and press the <Enter>...
Appendix E: System Specifi cations Appendix E System Specifi cations Processors Single or dual Intel® Xeon™ 5100/5000 Sequence processors at a front side (system) bus speed of 1333/1066/667 MHz. Note: Please refer to our web site for a complete listing of supported processors. Chipset Intel 5000P/ESB2 chipset BIOS...
Page 116
UPER ERVER 6015B-3R User's Manual Serverboard X7DBR-3 (Extended ATX form factor) Dimensions: 12 x 13.05 in (305 x 331 mm) Chassis SC815TQ-R650 Form Factor: 1U rackmount Dimensions: (WxHxD) 17 x 1.7 x 25.6 in. (432 x 43 x 650 mm) Weight Gross (Bare Bone): 41 lbs.
Page 117
Appendix E: System Specifi cations Regulatory Compliance Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR 22 Class A Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11) Safety: EN 60950/IEC 60950-Compliant, UL Listed (USA), CUL Listed (Canada), TUV Certifi...
Need help?
Do you have a question about the SUPERSERVER 6015B-3R and is the answer not in the manual?
Questions and answers