Troubleshooting - Water Depot PLATINUM SERIES Owner's Manual

Hide thumbs Also See for PLATINUM SERIES:
Table of Contents

Advertisement

Problem
1. Timer does not display time of
day
2. Timer does not display correct
time of day
3. No softening/filtering display
when water is flowing
4. Control valve regenerates at
wrong time of day
5. ERROR followed by code
number
Error code 1001 – Unable to
recognize start of regeneration
Error Code 1002 – Unexpected
stall
Error Code 1003 – Motor ran too
long, timed out trying to reach
next cycle position
Error Code 1004 – Motor ran to
long, timed out trying to reach
home position
If other Error Codes display
contact the factory.
TROUBLESHOOTING PROCEDURES
Possible Cause
a. AC adapter unplugged
b. No electric power at outlet
c. Defective AC adapter
d. Defective PC board
a. Switched outlet
b. Power outage
c. Defective PC board
a. Bypass valve in bypass
position
b. Meter connection disconnected
c. Restricted/stalled meter turbine
d. Defective meter
e. Defective PC board
a. Power outages
b. Time of day not set correctly
c. Time of regeneration
d. Control valve set at "on 0"
(immediate regeneration)
e. Control valve set at NORMAL +
on 0
a. Control valve has just been
serviced
b. Foreign mater is lodged in
control valve
c. High drive forces on piston
d. Control valve piston not in
home position
e. Motor not inserted fully to
engage pinion, motor wires
broken or disconnected motor
failure
f. Drive gear label dirty or
damaged, missing or broken gear
g. Drive bracket incorrectly
aligned to back plate
h. PC board is damaged or
defective
i. PC board incorrectly aligned to
drive bracket
Page 10
Solution
a. Connect Power
b. Repair outlet or use working
outlet
c. Replace AC Adapter
d. Replace PC board
a. Use uninterrupted outlet
b. Reset time of day
c. Replace PC board
a. Put bypass valve in service
position
b. Connect meter to PC board
c. Remove meter and check for
rotation or foreign material
d. Replace meter
e. Replace PC board
a. Reset control valve to correct
time of day
b. Reset to correct time of day
c. Reset regeneration time
d. Check control valve set-up
procedure regeneration time
option
e. Check control valve set-up
procedure regeneration time
option
a. Press NEXT and REGEN for 3
seconds or unplug power source
jack (black wire) and plug back in
to reset control valve
b. Check piston and spacer stack
assembly for foreign matter
c. Replace piston (s) and spacer
stack assembly
d. Press NEXT and REGEN for 3
seconds or unplug power source
jack (black wire) and plug back in
to reset control valve
e. Check motor and wiring.
Replace motor if necessary.
f. Replace or clean drive gear
g. Reset drive bracket properly
h. Replace PC board
i. Ensure PC board is correctly
snapped on to drive bracket