Step 1S – Press NEXT and  simultaneously for 3 seconds and release. If screen in Step 2S does
not appear in 5 seconds the lock on the valve is activated. To unlock press , NEXT, , and
CLOCK in sequence, then press NEXT and  simultaneously for 3 seconds and release.
Step 2S – Choose SOFTENING using the  or  button. Press NEXT to go to Step 3S. Press
REGEN to exit Softener System Setup.
Step 3S – Select the time for the first cycle (which in this example is BACKWASH) using the  or
 button. Press NEXT to go to Step 4S. Press REGEN to return to previous step.
Step 4S – Select the time for the second cycle (which in this example is dn BRINE) using the  or
 button. Press NEXT to go to Step 5S. Press REGEN to return to previous step.
NOTE: The display will . ash between cycle number and time, and brine direction (dn or UP).
Step 5S – Select the time for the third cycle (which in this example is RINSE) using the  or 
button. Press NEXT to go to Step 6S. Press REGEN to return to previous step.
Step 6S – Select the LBS for the fourth cycle (which in this example is FILL) using the  or
 button. Press NEXT to go to Step 7S. Press REGEN to return to previous step.
Step 7S –Set Grains Capacity using the  or  button. The ion exchange capacity is in grains of
hardness as calcium carbonate for the system based on the pounds of salt that will be used.
Calculate the pounds of salt using the fill time previously selected. The allowable grains capacity
range varies from 5000 to 500,000 grains. The increment increase is 500 for the range from 5000 to
50,000; 2000 for the range of 50,000 to 200,000; and 5000 for the range of 200,000 to 500,000.
Grains capacity is affected by the fill time. The grains capacity for the selected fill time should be
confirmed by testing. The capacity and hardness levels entered are used to automatically calculate
reserve capacity when gallon capacity is set to AUTO. Press NEXT to go to Step 8S. Press REGEN
to return to previous step.
Step 8S – Set Volume Capacity using the
• "AUTO" capacity will be automatically calculated and reserve capacity will be automatically estimated;
• "oFF" regeneration will be based solely on the day override set (see Installer Display Settings Step 3I); or
• as a number (allowable range 20 to 250,000) regeneration initiation will be based off the value specified.
Increment increase is 20 for the range 20 to 2000, 100 for the range of 2000 to 10,000, 500 for the range 10,000 to
50,000 and 2000 for the range of 50,000 to 250,000.
If "oFF" or a number is used, hardness display will not be allowed to be set in Installer Display Settings Step 2I.
See Table 8 for more detail. Press NEXT to go to Step 9S. Press REGEN to return to previous step.
STEP 9S
Step 9S – Set Regeneration Time Options using the
• "NORMAL" means regeneration will occur at the preset time;
• "on 0" means regeneration will occur immediately when the gallons capacity reaches 0 (zero); or
• "NORMAL + on 0" means regeneration will occur at one of the following:
— the preset time when the gallons capacity falls below the reserve or the specified number of days between
regenerations is reached, whichever comes first; or
— after 10 minutes of no water usage when the gallon capacity reaches 0 (zero).
See Table 8 for more detail. Press NEXT to go to Step 10S. Press REGEN to return to previous step.
or
button. If value is set to:
or
button. If value is set to: