Piusi Cube 56/33 Installation, Use And Maintenance Manual

Piusi Cube 56/33 Installation, Use And Maintenance Manual

Cube series
Hide thumbs Also See for Cube 56/33:

Advertisement

Installation, use and maintenance | EN
Installazione, uso e manutenzione | IT
Bulletin M0097D rev. 00 EnIT

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Cube 56/33 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Piusi Cube 56/33

  • Page 1 Installation, use and maintenance | EN Installazione, uso e manutenzione | IT Bulletin M0097D rev. 00 EnIT...
  • Page 2 Installation, use and maintenance ENGLISH Bulletin M0097D rev. 00 ENIT...
  • Page 3: Table Of Contents

    Environmental conditions Installation Mechanical installation 9.1. Hydraulic connections 9.2. Electrical connections 9.3. Starting Instructions for use Maintenance Troubleshooting Spare parts Manufacturer’s details and after-sales service 3/124 This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
  • Page 4: Ec Declaration Of Conformity

    ¦ Electromagnetic Compatibility Directive 2004/108/EC The documentation is at the disposal of the competent authority following motivated request at PIUSI S.p.A. or following request sent to the email address: doc_tec@piusi.com The person authorised to compile the technical file and draw up the declaration is Otto Varini as legal representative.
  • Page 5: General Information

    5/124 This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
  • Page 6: Safety Information

    Reproduction All reproduction rights are reserved by PIUSI S.p.A. rights The text cannot be reprinted without the written permission of PIUSI S.p.A. © PIUSI S.p.A.
  • Page 7 For safety reasons, we recommend that equipment be used only with a earth-leakage circuit breaker (max 30 mA). Electrical connections must use ground fault circuit interrupter (GFCI). 7/124 This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
  • Page 8 Installation, use and maintenance Equipment WARNING misuse Do not operate the unit when fatigued or under the influence of drugs or alcohol. Do not leave the working area while equipment is energized or under pressure. Turn off all equipment when equipment is not in use. Do not alter or modify equipment.
  • Page 9: First Aid Rules

    Wear the following personal protective equipment during handling Personal and installation: protective equipment that safety shoes protective gloves must be worn close-fitting clothings safety goggles Use Instruction Manual 9/124 This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
  • Page 10: Transport, Handling And Unpacking

    H = 480 mm / L = 380 mm / D = 380 mm Weight of packaging: 1,8 kg Total weight: CUBE 56/33 = 21,3 kg CUBE 70/33 = 24,0 kg CUBE DC 12V = 22,0 kg CUBE DC 24V = 22,0 kg...
  • Page 11: Using And Looking After Manuals

    EEC directive 89/391. Carefully read the instructions contained in these manuals, as these are most important for installation safety, operation and maintenance. 11/124 This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
  • Page 12: Cube Dispenser

    Installation, use and maintenance The manufacturer disclaims all liability for injury to persons or damage to things, or to machine, in the event of this being used in a way different to that indicated in the instructions. Look after this manual carefully in a place protected from damp, heat, dust, oils, greases, etc., as it will be useful for future reference and consultation.
  • Page 13: Cube Components

    In particular, those components that distinguish the various models of the CUBE product line are numbered and described. 1 ¦ Pump-Motor unit 2 ¦ Meter 13/124 This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
  • Page 14: Technical Specifications

    (l/m) cicle 230 V / 50 Hz - 1~ S1 (CONTINUO) CUBE 56/33 > 230/50 230 V / 60 Hz - 1~ S1 (CONTINUO) CUBE 56/33 > 230/60 110 V / 50 Hz - 1~ S1 (CONTINUO) CUBE 56/33 > 110/50...
  • Page 15: Permitted Uses

    Food liquids Liquids with viscosity > 20 cSt Motor overload Pump corrosion and/or injury to persons Corrosive chemical products Fire/explosion and/or damage to gasket seals Solvents 15/124 This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
  • Page 16: Environmental Conditions

    Installation, use and maintenance Environmental conditions Working temperature: -20°C min., +45°C max.; Relative humidity: 90% max. ATTENTION The specified limit temperatures apply to the pump components and must be complied with to avoid possible damage or faults. Extreme operating conditions can cause a motor temperature rise with consequent shutdown due to tripping of the overload circuit-breaker.
  • Page 17 The H º difference in height between the fuel surface and the pump in the Fuel surface dispenser must not be higher than 3 m! Tank 17/124 This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
  • Page 18: Mechanical Installation

    Installation, use and maintenance 9.1 Mechanical installation Before installation, verify that no packing material has been trapped in the tubing. Prepare suitable stilts or fixing brackets depending on the fixing position of CUBE. The hose coming from the tank must be aligned to the threaded inlet of the pump filter which is located under CUBE.
  • Page 19: Electrical Connections

    The maximum acceptable variations from the electrical parameters are: ¦ voltage +/- 5% ¦ frequency +/- 2% 19/124 This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
  • Page 20: Starting

    Installation, use and maintenance Connecting the Simply introduce the cable ATTENTION CUBE 230 V AC with the Schuko plug into single-phase the hole at the bottom of CUBE dispensers are not equipped with CUBE and connect the plug circuit breakers. It is therefore strongly to a grounded outlet of the recommended to install on the plug a household type.
  • Page 21 2 ¦ Stop delivery by closing the dispenser nozzle without stopping the pump. 3 ¦ Reset the partial counter by means of the reset knob (see: "how to dispense fuel" in paragraph 11). 21/124 This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
  • Page 22 Installation, use and maintenance 4 ¦ Dispense the fluid at the flow rate for which you require the highest possible metering precision into a graduated container with minimum capacity of 20 litres. Do not reduce the flow rate to bring the level to the graduated area of the container;...
  • Page 23: Instructions For Use

    Replace the nozzle (d). 6 ¦ Rehang the hose on the hose support hook, so that it will not be crushed by moving vehicles. 23/124 This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
  • Page 24: Maintenance

    Installation, use and maintenance Power loss An electrical power loss, with consequent undesired stoppage of the pump, may be caused by: ¦ tripping of safety systems; ¦ mains power failure. Irrespective of the cause, proceed as follows: 1 ¦ close the automatic nozzle; 2 ¦...
  • Page 25 Closing CUBE"); ¦ Screw off the 2 screws on the filter cover. To clean it, it is sufficient to wash it and blow through it. 25/124 This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
  • Page 26: Troubleshooting

    Installation, use and maintenance TROUBLESHOOTING Problem Possible causes Possible solutions ¦ Make sure the operating lever is in ON position ¦ Recock the external residual current circuit Lack of electric power breaker ¦ Check the electrical connections The motor is Fuses burned out Change the fuses on the switchboard not turning...
  • Page 27: Spare Parts

    CUBE SPARE PARTS - CUBE exploded diagram 27/124 This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
  • Page 28 Installation, use and maintenance RICAMBI - Pump exploded diagram Meter exploded diagram M0097D rev.00 ENIT...
  • Page 29: Manufacturer's Details And After-Sales Service

    Technical Support: Provided by the Service Departments of our Authorized Resellers The information contained in this manual is provided by the manufacturer, who reserves the right to make changes without prior notice. 29/124 This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.

This manual is also suitable for:

Cube 70/33Cube 90/44Cube dc

Table of Contents