Connecting The Grounding Cable To The Chassis - HP FlexFabric 5980 48SFP+6QSFP28 Installation Manual

Flexfabric 5980 series
Table of Contents

Advertisement

Figure 7 Attaching the mounting brackets and chassis rails to the switch (power supply-side
mounting position for the mounting brackets)
Figure 8 Attaching the mounting brackets and chassis rails to the switch (network port-side
mounting position for the mounting brackets)
NOTE:
Attach the mounting brackets and chassis rails to both sides of the chassis in the same way.

Connecting the grounding cable to the chassis

CAUTION:
The primary grounding point and auxiliary grounding point 1 are located on the left panel of the
chassis. If you use one of these grounding points, you must connect the grounding cable to the
grounding point before you mount the switch in the rack.
The grounding cable and grounding screw that come with the switch are applicable to both the
primary and auxiliary grounding points.
To connect the grounding cable:
1.
Choose a grounding point as required.
This example uses the primary grounding point.
2.
Unpack the grounding cable and grounding screws.
3.
Use two grounding screws to attach the two-hole grounding lug of the grounding cable to the
grounding holes at the grounding point. Use a screwdriver to tighten the screws. See
10
Figure
9.