emmeti CS-11 User Manual

emmeti CS-11 User Manual

Lcd digital setback thermostat

Advertisement

Quick Links

Buttons and LCD display
Buttons
Press < 5 seconds
Turning on/off thermostat
M
Confirm settings
Increase the set value
Decrease the set value
+
M
+
Configure the menu
First turn off the thermostat using the on/off button
M
Press and hold button
for 5 seconds. Now you can see Menu 01, to proeceed to other menu, press button
Feature Description
Menu #
Sensor selection. This thermostat is a combination model allowing you to choose
between 3 different models. (A, AF,F )
01
A model:
air onl y, with built in sensor
AF model: air & floo r , with both built in and remote sensor
F model:
floor only, with remote sensor
Select temperature format
02
03
Calibrate the room temperature. This feature is used to compensate for any difference
between the displayed room temperature and a thermometer.
Calibrate the floor temperature. This feature is used to compensate for any difference
04
between the displayed floor temperature and a thermometer.
Set the floor temperature limit.
05
Switching differential.
The default is 1°C which means the thermostat will switch the heating on
0.5°C below the set temperature and will turn it off 0.5°C above the set temperature.
06
With a 2°C differential, the heating will switch on 1°C below the set temperature
and will switch off 1°C above the set temperature.
Frost protection. This is to avoid room temperature goes below 5°C.
07
08
The setback amount( the amount of temperature reduction)
This gives you the option to limit the minimum set temperature
09
10
This gives you the option to limit the maximum set temperature
WARNING
1. Please ensure that the electrical wiring of the installation and connections to and from the thermostat and any remote sensor connected to it are in accordance with BS 7671, the latest edition of the IET
Wiring Regulations.
2. The thermostat must be wired to the electric mains through a switch capable of disconnecting all poles compliant with the current safety standards and with a contact separation of at least 3 mm in all poles.
3. Before commencing work on the installation, the electricity supply must be disconnected.
4. The depth of the back box should be 35mm minimum.
Setting temperature
Press
or
once, you will see set temperature flashing. Use
to the temperature you want your room to maintain. Press button
Resetting factory defaults
Your thermostat has the ability to reset all settings to the factory defaults. If you are certain you want
to do this: In standby mode(when thermostat is turned off), press and hold button
for 5 seconds until RES is shown on LCD.
Please Note: one of the following error messages will appear if one of these problems occur:
E0, meaning the internal sensor is broken, short-circuit or not working properly.
E1, meaning the floor sensor is broken, short-circuit, not connected, or not working properly.
U9310090
CS-11 LCD Digital Setback Thermostat
Press > 5 seconds
Menu button
Lock /unlock buttons
Reset to factory settings
(when thermostat is turned off)
°C or °F.
This feature is to protect the floor surface.
The numbers of degree difference before switching.
or
again to adjust
to accept and exit.
M
Registered Address: 6 Tannery Yard, Witney Street, Burford, Oxon., OX18 4DW
Tel: 01993 824900 : www.emmeti.co.uk : e: sales@emmeti.co.uk
Symbol
Description
Set temperature
Set At
The buttons are locked.
Displays when heating is active
Setback mode
Installation and Wiring
Carefully separate the front half of the thermostat from the back plate by placing a
small flat head terminal driver into the slots on the bottom face of the thermostat.
Carefully unplug the ribbon connector which is plugged in to the front half of the thermostat.
Place the thermostat front half somewhere safe. Make the wiring connections as
shown in the diagram below.
Screw the thermostat back plate on to the back box.
Re-connect the thermostat ribbon cable and clip the
two halves together.
and
M
again. To exit menu, press button
Factory Default
Press
Feature Value
A
°C
0°C
0°C
40 °C
1°C
off
4°C
10°C
35°C
Remote sensor for floor
temperature control
Timeswitch live
for operation
of temperature
setback mode
or
to select
A / AF / F
°C / °F
-5°C ~ +5°C
-5°C ~ +5°C
20°C ~ 40 °C
1°C ~ 5°C
on / off
2°C~ 7°C
10°C~ 20°C
20°C~ 35°C
1
ErP Class
+1%
Single Zone
8
ErP Class
+5%
Multi Zone
Link terminals 1
to 3 for 230VAC
live output
N
L
Switched live
230V ~ 50Hz
output