Object 0X6048: Vl_Velocity_Acceleration; Object 0X6049: Vl_Velocity_Deceleration; Object 0X604A: Vl_Velocity_Quick_Stop; Object 0X605A: Quick Stop Option Code - Toshiba TOSVERT VF-MB1 Function Manual

Tosvert vf-mb1/s15 series ethercat option unit ipe003z
Hide thumbs Also See for TOSVERT VF-MB1:
Table of Contents

Advertisement

6.1.10. Object 0x6048: vl_velocity_acceleration

This object indicates the configured delta speed and delta time of the slope of the
acceleration ramp.
Note: Do not change the acceleration/deceleration time unit (parameter f519), if
change the parameter, the setting value range will be different from above range.

6.1.11. Object 0x6049: vl_velocity_deceleration

This object indicates the configured delta speed and delta time of the slope of the
deceleration ramp.
Note: Do not change the acceleration/deceleration time unit (parameter f519), if
change the parameter, the setting value range will be different from above range.

6.1.12. Object 0x604A: vl_velocity_quick_stop

This object indicates the configured delta speed and delta time of the slope of the
deceleration ramp for quick stop.
deceleration ramp.
Note: Do not change the acceleration/deceleration time unit (parameter f519), if
change the parameter, the setting value range will be different from above range.

6.1.13. Object 0x605A: Quick stop option code

This object shall indicate what action is performed when the quick stop function is
executed.
The slow down ramp is the deceleration value of the used mode of operations.
-32768 to -1
+9 to +32 767
*Not supported these values. Do not set these values. If set the value 5-8, the drive slow
down ramp and transit into Switch On Disabled.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Velocity Acceleration Delta Speed
Velocity Acceleration Delta Time
Velocity Deceleration Delta Speed
Velocity Deceleration Delta Time
Velocity Deceleration Delta Speed
Velocity Deceleration Delta Time
Value
No function
0
Disable drive function
+1
Slow down on slow down ramp and transit into Switch On Disabled
+2
Slow down on quick stop ramp and transit into Switch On Disabled
+3
Do not set
+4
Slow down on voltage limit and transit into Switch On Disabled
+5*
Slow down on slow down ramp and stay in Quick Stop Active
+6*
Slow down on quick stop ramp and stay in Quick Stop Active
+7*
Do not set
+8*
Slow down on voltage limit and stay in Quick Stop Active
Reserved
: 225 to 30,000 min
: 0.1 to 3,600 s
: 225 to 30,000 min
: 0.1 to 3,600 s
: 225 to 30,000 min
: 0.1 to 3,600 s
Definition
- 31 -
E6581818
-1
-1
-1