Toshiba TOSVERT VF-MB1 Function Manual page 11

Tosvert vf-mb1/s15 series ethercat option unit ipe003z
Hide thumbs Also See for TOSVERT VF-MB1:
Table of Contents

Advertisement

Communi
Title
cation No.
c021
C021
Scanner output 1 address
c022
C022
Scanner output 2 address
c023
C023
Scanner output 3 address
c024
C024
Scanner output 4 address
c025
C025
Scanner output 5 address
c026
C026
Scanner output 6 address
c041
C041
Scanner input 1 value
c042
C042
Scanner input 2 value
c043
C043
Scanner input 3 value
c044
C044
Scanner input 4 value
c045
C045
Scanner input 5 value
c046
C046
Scanner input 6 value
c061
C061
Scanner output 1 value
c062
C062
Scanner output 2 value
c063
C063
Scanner output 3 value
c064
C064
Scanner output 4 value
c065
C065
Scanner output 5 value
c066
C066
Scanner output 6 value
Communication error
c100
C100
detection delay time
Inverter operation at the
c101
C101
communication loss action
Preset speed
c102
C102
operation selection
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Function
0: None
1: fd01 (Inverter status 1)
2: fd00 (Output frequency, 0.01Hz)
3: fd03 (Output current, 0.01%)
4: fd05 (Output voltage, 0.01%)
5: fc91 (Inverter alarm)
6: fd22 (PID feedback value, 0.01Hz)
7: fd06 (Input terminal status)
8: fd07 (Output terminal status)
9: fe36 (VIB input, 0.01%)
10: fe35 (VIA input, 0.01%)
11: fe37 (VIC input, 0.01%)
12: fd04 (Input voltage (DC detection), 0.01%)
13: fd16 (Estimated speed
14: fd18 (Torque, 0.01%)
19: f880 (Free notes)
20: fd29 (Input power, 0.01kW)
21: fd30 (Output power, 0.01kW)
22: fe14 (Cumulative operation time,
23: fe40 (FM terminal output monitor, 0.01%)
25: fd20 (Torque current, 0.01%)
26: fd23 (Motor overload factor, 0.01%)
27: fd24 (Drive overload factor, 0.01%)
28: fd25 (PBR overload factor, %)
29: fd26 (Motor load factor, %)
30: fd27 (Drive load factor, %)
31: fe56 (Pulse train input, pps)
32: fe70 (Drive rated current, 0.1A)
33: fe76 (Input Watt-hour, 1kWh  10
34: fe77 (Output Watt-hour, 1kWh  10
35: fd83 (IGBT temperature, degree C)
100: ETA
101: RFRD
0-101 (Same as c021)
0-101 (Same as c021)
0-101 (Same as c021)
0-101 (Same as c021)
0-101 (Same as c021)
The argument value set to c001 is displayed.
The argument value set to c002 is displayed.
The argument value set to c003 is displayed.
The argument value set to c004 is displayed.
The argument value set to c005 is displayed.
The argument value set to c006 is displayed.
The argument value set to c021 is displayed.
The argument value set to c022 is displayed.
The argument value set to c023 is displayed.
The argument value set to c024 is displayed.
The argument value set to c025 is displayed.
The argument value set to c026 is displayed.
0.0 - 100.0 sec.
0: Stop and controlled by cmod, fmod
1: Operation continue
2: Deceleration stop
3: Coast stop
4: Network error stop (err8 trip)
5: Preset speed operation (by c102 setting)
0: None
1 to 15: Preset speed
- 10 -
Description
(real-time value), 0.01Hz)
0.01 = 1 hour)
E6581818
Default
2
3
100*
*
f749
)
f749
)
2
3
101*
*
2
3
-*
*
2
3
-*
*
2
3
-*
*
2
3
-*
*
3
-*
3
-*
3
-*
3
-*
3
-*
3
-*
3
-*
3
-*
3
-*
3
-*
3
-*
3
-*
0.1<
-
-