5.2.1.12. fc91 (Alarm code)
Function
bit
0
Over-current alarm
1
Inverter over load alarm
2
Motor over load alarm
3
Over heat alarm
4
Over voltage alarm
5
Main circuit undervoltage alarm
6
main device overheat alarm
7
Under current alarm
8
Over-torque alarm
9
Braking resistor overload alarm
10
Cumulative operation hours alarm
11
Option communication alarm
12
Serial communication alarm
13
MOFFMS (MSrelay off or MOFF)
14
Stop after instantaneous power off
15
Stop after LL continuance time
5.2.1.13. fd06 (Input TB Status)
bit
TB Name
0
F
1
R
2
RES
3
S1
4
S2
5
S3
6
VIB*1
7
VIA*1
5 to 15
(Undefined) -
Note: The bit described "Undefined" is unstable. Do not use the bit for the judgment.
*1: VIA/ VIB are input terminal function when f109 is logic input.
*The input terminal function is selected by each parameter.
5.2.1.14. fd07 (Output TB Status)
bit
TB Name
0
RY-RC
1
OUT
2
FL
3 - 15
(Undefined)
Note: The bit described "Undefined" is unstable. Do not use the bit for the judgment.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Function (Parameter)
Input terminal function selection 1 (f111)
Input terminal function selection 2 (f112)
Input terminal function selection 3 (f113)
Input terminal function selection 4 (f114)
Input terminal function selection 5 (f115)
Input terminal function selection 6 (f116)
Input terminal function selection 7 (f117)
Input terminal function selection 8 (f118)
Function (Parameter)
Output terminal function selection 1A (f130)
Output TB Function select 2A (f131)
Output TB Function select 3 (f132)
-
- 23 -
0
1
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Normal
Alarming
Dec., Under
-
stop
Dec., Under
-
stop
OFF
OFF
OFF
OFF
E6581818
Remarks
(Code displayed on
the panel)
c flicking
l flicking
l flicking
h flicking
p flicking
-
l flicking
-
-
-
-
-
-
-
Refer to f302
value
Refer to f256
value
0
1
ON
-
-
0
1
ON
ON
ON
-
-