Clear History - Magnetek 2001-G+M Instruction Manual

Impulse-g+ mini series adjustable frequency crane controls
Hide thumbs Also See for 2001-G+M:
Table of Contents

Advertisement

Parameter
Code
O02.05
O02.07

Clear History

Parameter
Code
O03.01
IMPULSE•G+ Mini Advanced Instruction Manual – March 2014
5-86
Name
Function
63 2A0006
2005-G+M
64 --
Not used
65 2A0010
2008-G+M
66 2A0012
2011-G+M
67 2A0018
Not used
68 2A0020
2017-G+M
69 --
Not used
6A 2A0030
2025-G+M
6B 2A0040
2033-G+M
6C --
Not used
6D 2A0056
2047-G+M
6E 2A0069
2060-G+M
91 4A0001
4001-G+M
92 4A0002
4002-G+M
93 4A0004
4003-G+M
94 4A0005
4004-G+M
95 4A0007
4005-G+MF (OEM only)
96 4A0009
4007-G+MF (OEM only)
97 4A0011
4009-G+M
98 --
Not used
99 4A0018
4014-G+M
9A 4A0023
4018-G+M
9B --
Not used
9C 4A0031
4024-G+M
9D 4A0038
4031-G+M
Operator M.O.P.
Selects whether the ENTER key is
used when the frequency reference is
set by the digital operator. The digital
operator can simulate a motor
operated potentiometer (M.O.P.) by
setting this parameter.
00 Disabled
ENTER Key Required
01 Enabled
ENTER Key Not Required
Motor Direction at Power-
Sets direction of motor at power-up.
Up
00 Forward
01 Reverse
Name
Function
Elapsed Time Setting
--
Initial
Access
Range
Value
Level
00, 01
00
Adv
Note: This feature cannot be used in
conjunction with infinitely variable
speed control.
00, 01
00
Adv
Initial
Access
Range
Value
Level
0000–9999hr 0000
Adv

Hide quick links:

Advertisement

Table of Contents
loading