IPM Continuity Check

Turn off the power, let the large capacity electrolytic capacitors discharge completely, and dismount the IPM. Use a digital tester to measure the
resistance between P and UVWN; UVW and N.
Digital Tester
(+)Red
(-)Black
N
U
P
V
W

Fan Motor

Measure the resistance value of each winding by using the tester.
Model
Brand
Black – Red
Ω
Main
Blue –Black
Ω
AUX
44
Table 16—IPM Continuity Check
Normal Resistance Value
(Several MΩ)
Table 17—Fan Motor
YKT-32-6-202L
YKT-32-6-3L
Tongde
86
64
Specifications subject to change without notice.
Digital Tester
(+)Red
(-)Black
U
V
N
W
(+)Red
YKT-48-6-206
Welling
Welling
213
152
156
142
Normal Resistance Value
(Several MΩ)
YKT-63-6-200L
Welling
88.5
138