OUTDOOR UNIT DIAGNOSTIC GUIDES

OPERATION LAMP
TIMER LAMP
1 time
2 times
3 times
4 times
5 times
6 times
7 times
1 time
2 times
3 times
4 times
5 times
6 times
1 time
2 times
3 times
4 times
5 times
6 times
32808001101
Table 11—Diagnostic Guides
DISPLAY
X
Indoor unit EEPROM parameter error
E0
X
Indoor / outdoor units communication error
E1
X
Zero-crossing signal detection error
E2
X
Indoor fan speed has been out of control
E3
X
Indoor room temperature sensor T1 open circuit or short circuit
E4
X
Evaporator coil temperature sensor T2 open circuit or short circuit
E5
X
Refrigerant leakage detection
EC
O
Overload current protection
F0
O
Outdoor ambient temperature sensor T4 open circuit or short circuit
F1
O
Condenser coil temperature sensor T3 open circuit or short circuit
F2
O
Compressor discharge temperature sensor T5 open circuit or short circuit
F3
O
Outdoor unit EEPROM parameter error
F4
O
Outdoor fan speed has been out of control
F5
IPM malfunction or IGBT over-strong current protection
P0
Over voltage or over low voltage protection
P1
High temperature protection of IPM module or compressor top
P2
Outdoor ambient temperature too low.
P3*
Inverter compressor drive error
P4
Indoor units mode conflict (multi-zone ONLY)
P5
O(light)
Specifications subject to change without notice.
LED STATUS
☆(flash)
X(off)
23