DISASSEMBLY INSTRUCTIONS SIZES 24K (208−230V) (CONT)
4
Four-way
valve
5
Compressor
32808001101
How to remove the
four-way valve.
1) Complete the steps in
sections 1, 3.
2) Recover the refrigerant
from the refrigerant
circuit.
3) Remove the coil screw
and then remove the
coil.
4) Detach the welded
parts of four-way valve
and pipe.
5) Remove the four-way
valve assembly.
How to remove the
compressor.
1) Complete steps in
sections 1, 3. Recover
refrigerant from the
refrigerant circuit.
2) Remove the discharge
and suction pipes with
a burner.
3) Remove the hex nuts
and washers securing
the compressor to the
bottom plate.
4) Lift the compressor
from the base pan
assembly.
Specifications subject to change without notice.
The picture of four-way valve may differ from your
actual valve.
3
2
4
69