Midea Split Type Room Air Conditioner Owner's Manual
Midea Split Type Room Air Conditioner Owner's Manual

Midea Split Type Room Air Conditioner Owner's Manual

Split type room air conditioner

Advertisement

OWNER S MANUAL

Split Type Room Air Conditioner
Please read the operating instructions and safety precautions carefully and thoroughly
before installing and operating your room air conditioner.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Split Type Room Air Conditioner and is the answer not in the manual?

Questions and answers

Summary of Contents for Midea Split Type Room Air Conditioner

  • Page 1: Owner S Manual

    OWNER S MANUAL Split Type Room Air Conditioner Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air conditioner.
  • Page 2: Table Of Contents

    CONTENTS SAFETY PRECAUTIONS ..................PARTS NAMES ..................... OPERATING TEMPERATURE ................MANUAL OPERATION ..................ADJUSTING AIR FLOW DIRECTION..............HOW THE AIR CONDITIONER WORKS..............OPTIMAL OPERATION ..................MAINTENANCE....................... OPERATION TIPS ....................TROUBLESHOOTING TIPS................... Read This Manual Inside you will find many helpful hints on how to use and maintain your air conditioner properly.
  • Page 3: Safety Precautions

    Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications. WARNING This symbol indicates the possibility of death or serious injury.
  • Page 4 ! CAUTION When the air filter is to be Do not clean the air Ventilate the room well when removed, do not touch the conditioner with water. used together with a stove, etc. metal parts of the unit. It may cause an injury. Water may enter the unit and An oxygen shortage may occur.
  • Page 5: Parts Names

    PARTS NAMES Indoor unit NOTE: The indoor unit you purchased would like one of the following. There is a slightly difference on front panel and display window, but the features are the same. Indoor unit Air inlet 1. Front panel 2.
  • Page 6: Operating Temperature

    OPERATING TEMPERATURE Mode Cooling operation Heating operation Drying operation Temperature 17 C 32 C Room temperature 30 C 17 C 32 C 18 C 43 C 11 C 43 C ( -5 C 43 C:For the models with Outdoor temperature -7 C 24 C 21 C...
  • Page 7: Adjusting Air Flow Direction

    ADJUSTING AIR FLOW DIRECTION Adjust the air flow direction properly otherwise, it might cause discomfort or cause uneven room temperatures. Adjust the horizontal louver using the remote controller. Adjust the vertical louver manually. Adjusting the Vertical Air Flow Direction (up - down) The air conditioner automatically adjusts the vertical air flow direction in accordance with the operating mode.
  • Page 8: How The Air Conditioner Works

    HOW THE AIR CONDITIONER WORKS AUTOMATIC OPERATION ECONOMIC (SLEEP) operation When you set the air conditioner in AUTO mode, it will automatically select cooling, heating(cooling/heating models only), or fan only operation depending on what temperature you have selected and the room temperature. Temperature The air conditioner will control room temperature automatically round the temperature point set by you.
  • Page 9: Maintenance

    MAINTENANCE WARNING It is necessary to stop the air conditioner and dis- Household connect the power supply before cleaning. Drain Cleaner Cleaning the indoor unit and remote controller CAUTIONS Use a dry cloth to wipe the indoor unit and remote controller.
  • Page 10 MAINTENANCE 4. Remove the Air Freshening Filter(Optional filter: Plasma Dust Collector/ Silver Ion filter /Bio filter / Vitamin C filter/3M air purifier filter) from its support frame.(There is slightly difference on installation/ removing the filter, see the pictures marked Air freshening on the left.
  • Page 11: Operation Tips

    OPERATION TIPS The following events may occur during normal operation. Protection of the air conditioner. Compressor protection The compressor can't restart for 3 minutes after it stops. Anti-cold air (Cooling and heating models only) The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in one of the following three situations and the set temperature has not been reached.
  • Page 12 7. Dripping water may generate on the surface of the indoor unit when cooling in a high relatively humidity (relative humidity higher than 80%). Adjust the horizontal louver to the maximum air outlet position and select HIGH fan speed. Heating mode (For cooling and heating models only) The air conditioner draws in heat from the outdoor unit and releases it via the indoor unit during heating operation.
  • Page 13: Troubleshooting Tips

    Troubleshooting tips Malfunctions and Solutions Stop the air conditioner immediately if one of the following faults occur. Disconnect the power and contact the nearest customer service center. OPERATION indicator or other indicators flash rapidly (5 times every second) and this flash can't be fixed by disconnecting the power, and then connect it in again. Trouble Fuse blows frequently or circuit breaker trips frequently.
  • Page 14 CS0159(B) 2200019586...