DISASSEMBLY INSTRUCTIONS SIZES 9−12K (208−230V) (CONT)
4
Four-way
valve
5
Compressor
32808001101
How to remove the
four-way valve.
1) Complete the steps in
sections 1, 3.
2) Recover refrigerant
from the refrigerant
circuit.
3) Remove the coil
screw then remove
the coil.
4) Detach the welded
parts of the four-way
valve and pipe.
5) Remove the four-way
valve assembly.
How to remove the
compressor.
1) Complete steps in
sections 1, 3.
2) Recover refrigerant
from the refrigerant
circuit.
3) Remove the
4) discharge and suction
pipes with a burner.
5) Remove the hex nuts
and washers securing
the compressor on
the bottom plate.
6) Lift the compressor
from the base pan
assembly.
Specifications subject to change without notice.
The picture of four-way valve may differ from your
actual valve.
3
3
4
2
57