Midea DLCERAA12AAJ Service Manual page 63

Dlcera series outdoor unit single zone ductless system - sizes 09 to 24
Table of Contents

Advertisement

DISASSEMBLY INSTRUCTIONS SIZES 18K (208−230V) (CONT)
4
Four-way
valve
5
Compressor
32808001101
How to remove the
four-way valve.
1) Complete the steps in
sections 1, 3.
2) Recover refrigerant
from the refrigerant
circuit.
3) Remove the coil screw
then remove the coil.
4) Detach the welded
parts of four-way valve
and pipe.
5) Remove the four-way
valve assembly.
How to remove the
compressor.
1) After completing steps
in sections 1, 3,
recover refrigerant
from the refrigerant
circuit.
2) Remove the discharge
and suction pipes with
a burner.
3) Remove the hex nuts
and washers securing
the compressor on the
bottom plate.
5) Lift the compressor
from the base pan
assembly.
Specifications subject to change without notice.
The picture of four-way valve may differ from your
actual valve.
3
2
3
63