DISASSEMBLY INSTRUCTIONS SIZES 12K (115V) (CONT)
3
Electrical
parts
50
How to remove the
electrical parts.
1) After you complete the
steps in item 1 and 2,
remove the compressor
connector.
2) Pull out the two blue
wires connected to the
four way valve.
3) Pull out connectors of
the condenser coil
temp. sensor (T3),
outdoor ambient temp.
sensor (T4) and
discharge temp. sensor
(T5).