Ipm Continuity Check - Midea MSMBB-12CRDN1-MP0W Service Manual

Mission mini split 3d dc inverter air conditioner
Table of Contents

Advertisement

3. IPM continuity check

Turn off the power, let the large capacity electrolytic capacitors discharge completely, and dismount the IPM. Use a digital
tester to measure the resistance between P and UVWN; UVW and N.
Digital tester
(+)Red
(-)Black
N
U
P
V
W
4.Indoor AC Fan Motor
Measure the resistance value of each winding by using the tester.
Position
Black - Red
White - Black
Normal resistance value
(Several MΩ)
RPG20E(YKFG-20-4-5)
388Ω±8% (20℃)
(Brand: Weiling)
360Ω±8% (20℃)
(Brand: Weiling)
Digital tester
(+)Red
(-)Black
U
V
W
(+)Red
Resistance Value
RPG28D(YKFG-28-4-1)
260Ω±8% (20℃)
(Brand: Weiling)
385Ω±8% (20℃)
(Brand: Weiling)
53
Normal resistance value
N
(Several MΩ)
RPG45C(YKFG-45-4-22)
168Ω±8% (20℃)
(Brand: Weiling)
141Ω±8% (20℃)
(Brand: Weiling)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msmbc-18crdn1-mp0wMsmbd-22crdn1-mp5w

Table of Contents