Page 1
UPS T2200 XR Operation and Reference Guide First Edition (November 2000) Part Number 215503-001 Compaq Computer Corporation...
Page 2
Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor’s standard commercial license. Compaq shall not be liable for technical or editorial errors or omissions contained herein. The information in this document is subject to change without notice. The warranties for Compaq products are set forth in the express limited warranty statements accompanying such products.
Compaq Technical Support ..................x Compaq Website ....................xi Compaq Authorized Reseller................xi Chapter 1 Overview Compaq UPS T2200 XR Models................1-2 Front Panels ......................1-3 Rear Panels ......................1-4 Standard UPS Features .................... 1-8 Communications Port ..................1-9 UPS Power Management Software ..............1-9 Hardware Option Cards ..................
Page 4
Compaq UPS T2200 XR Operation and Reference Guide Chapter 2 Installation Installation Requirements ..................2-2 Item(s) not supplied with the UPS kit............... 2-2 Item(s) supplied with the UPS kit ..............2-2 Before Starting the UPS................... 2-3 Connecting to the Communications Port ............2-4 Connecting the Network Transient Protector............
Page 5
About This Guide v Chapter 5 Battery Maintenance Precautions....................... 5-2 Charging Batteries ....................5-2 When to Replace Batteries..................5-2 Pre-Failure Battery Warranty................... 5-3 Obtaining New Batteries..................5-4 Replacing Batteries....................5-4 Step 1: Preparing the UPS ................5-4 Step 2: Removing the Battery Pack ..............5-5 Step 3: Installing New Batteries ...............
About This Guide This guide is designed to be used as step-by-step instructions for installation and as a reference for operation, troubleshooting, and future upgrades. Text Conventions This document uses the following conventions to distinguish elements of text: Keys Keys appear in boldface. A plus sign (+) between two keys indicates that they should be pressed simultaneously.
Compaq UPS T2200 XR Operation and Reference Guide Symbols in Text These symbols may be found in the text of this guide. They have the following meanings. WARNING: Text set off in this manner indicates that failure to follow directions in the warning could result in bodily harm or loss of life.
WARNING: There is a risk of electric shock from high Earth (ground) conductor leakage current when connecting multiple pieces of Information Technology Equipment to Compaq Uninterruptible Power Systems (UPS): The summation of the input power for multiple pieces of Information Technology Equipment through the use of a UPS can result in high Earth conductor leakage current.
Compaq UPS T2200 XR Operation and Reference Guide WARNING: The UPS T2200 XR models weigh 70 lb (32 kg) when fully assembled. To reduce the risk of personal injury or damage to the equipment: 70 lb Observe local occupational health and safety requirements and guidelines 32 kg for manual material handling.
About This Guide xi Compaq Website For more information on Compaq products, access the Compaq website at www.compaq.com. Compaq Authorized Reseller For the name of the nearest Compaq authorized reseller: In the United States, call 1-800-345-1518. In Canada, call 1-800-263-5868.
Chapter Overview This chapter contains information on the following topics: Compaq Uninterruptible Power System (UPS) T2200 XR models UPS T2200 XR front panels UPS T2200 XR rear panels UPS T2200 XR features Warranties...
IEC-320 input power receptacle WARNING: Risk of personal injury from electric shock. The UPS T2200 XR H NA and T2200 XR H INT’L models are not suitable for installation where the total Earth (ground) conductor leakage current for all...
Overview 1-3 Front Panels The UPS T2200 XR models are all tower configuration. Figure 1-1. Front panel configuration LED Display Button controls Battery compartment...
1-4 Compaq UPS T2200 XR Operation and Reference Guide Rear Panels The UPS T2200 XR models feature the following rear panel configurations: Figure 1-2. Rear panel of T2200 XR NA Communications port/Option slot Load segment 1 (three NEMA 5-15 receptacles)
Page 16
Overview 1-5 Figure 1-3. Rear panel of T2200 XR JPN Communications port/Option slot Load segment 1 (three NEMA 5-15 receptacles) Network Transient Protector Load segment 3 (two NEMA 5-20 IN jack receptacles) Network Transient Protector Circuit protector OUT jack Circuit protectors...
Page 17
Load segment 2 (three IEC-320-C13 receptacles) WARNING: Risk of personal injury from electric shock. The UPS T2200 XR H NA model is not suitable for installation where the total Earth (ground) conductor leakage current for all connected devices exceeds 3.5 mA.
Page 18
Load segment 3 (three ERM connector IEC-320-C13 receptacles) WARNING: Risk of personal injury from electric shock. The UPS T2200 XR H INT’L model is not suitable for installation where the total Earth (ground) conductor leakage current for all connected devices exceeds 3.5 mA.
Communications port for data exchange with the host computer Power protection features The T2200 XR-NA model includes load protection up to 1920VA/1600W T2200 XR-H NA, T2200 XR-JPN, and T2200 XR-H INT’L models include load protection up to 2200VA/1600W Load segment control Support for UPS power management software...
Overview 1-9 Communications Port The UPS T2200 XR models include a communications port for data exchange with the host computer. The UPS power management software supplied by Compaq enables the user to access status reporting and power management features. CAUTION: Use only specific Compaq cables supplied with your T2200 UPS kit to connect the communications port to the host computer.
With two ERMs, the UPS available runtime is approximately 30 minutes or greater. WARNING: The UPS T2200 XR Extended Runtime Modules weigh 77 lb (35 kg). Observe local occupational health and safety requirements and guidelines, and obtain adequate assistance to lift and stabilize the equipment.
Warranties $25,000 Computer Load Protection Guarantee To back up the wide range of features offered with the UPS, Compaq provides a three-year limited warranty. In addition, Compaq offers a $25,000 Computer Load Protection Guarantee (provided by the original equipment manufacturer).
Chapter Installation This chapter provides information on the following topics: Installation requirements Procedures to complete before starting the UPS Starting the UPS Completing the installation...
30A for low voltage T2200 XR JPN models 20A for low voltage T2200 XR NA models 10A for high voltage T2200 XR H NA and T2200 XR H INT’L models Item(s) supplied with the UPS kit The UPS kit should contain the following components:...
WARNING: Risk of personal injury from electric shock. The UPS T2200 XR H NA and T2200 XR H INT’L models are not suitable for installation where the total Earth (ground) conductor leakage current for all connected devices exceeds 3.5 mA.
2-4 Compaq UPS T2200 XR Operation and Reference Guide Connecting to the Communications Port The UPS T2200 XR models include a communications port that allows the UPS to exchange data with the host computer. IMPORTANT: UPS power management software requires the communications port to be appropriately cabled to the host computer.
Installation 2-5 Connecting the Network Transient Protector The UPS T2200 XR models include a Network Transient Protector that allows the UPS to protect a communications device from surges. IMPORTANT: Use the Network Transient Protector with a standard telephone line only;...
2-6 Compaq UPS T2200 XR Operation and Reference Guide Starting the UPS Starting the UPS for the first time requires the following procedures: Checking the Battery Recharge Date label on the UPS shipping carton Connecting the UPS to utility power via the input power cord...
After verifying that the UPS will not overload, connect the power cords from the devices to the appropriate output receptacles of the UPS. WARNING: Risk of personal injury from electric shock. The UPS T2200 XR H NA and T2200 XR H INT’L models are not suitable for installation where the total Earth (ground) conductor leakage current for all connected devices exceeds 3.5 mA.
2-8 Compaq UPS T2200 XR Operation and Reference Guide Powering up the UPS When the unit is plugged in for the first time, the UPS automatically initiates a self-test. The front panel LED display lights will go on and off during the self-test.
IMPORTANT: The batteries will charge to 90 percent of their capacity within less than 3 hours. Compaq recommends allowing the batteries to charge for 24 hours before using the UPS to supply backup power to devices. The load may not be fully protected for...
2-10 Compaq UPS T2200 XR Operation and Reference Guide Placing the UPS in Operate mode Press and hold the ON button (2) until the Utility LED (1) turns solid green, indicating that power is available at the UPS output receptacles. The UPS will acknowledge compliance with a short beep.
Chapter Operation This chapter contains information on the following topics: Precautions to be observed when using the UPS UPS modes of operation Front panel controls Front panel indicators Placing the UPS in Operate mode Returning to Standby mode Initiating a self-test The audio alarm...
3-2 Compaq UPS T2200 XR Operation and Reference Guide Precautions Observe these precautions when using the Compaq UPS T2200 XR models. WARNING: To reduce the risk of electric shock from Earth (ground) conductor leakage current: Do not operate a UPS that is disconnected from the utility power source.
Operation 3-3 Front Panel Controls The UPS T2200 XR model front panels include the controls required to: Place the UPS in Operate mode. Place the UPS in Standby mode. Place the UPS in Configure mode using button beneath front bezel.
Page 36
3-4 Compaq UPS T2200 XR Operation and Reference Guide The front panel includes the following LED indicators and button controls: Figure 3-1. Front panel LED display and controls when front bezel removed Overload LED 76% to 100% load 51% to 75% load...
Operation 3-5 Front Panel Indicators The front panel LED display colors indicate the UPS status: Green LEDs indicate normal conditions Red LEDs provide warning of existing or potential problems LEDs are referred to as LED 1 through 10 (LED 11 indicates that Configure mode is ON and is only accessible during Configure mode when the front bezel is removed), as described in this documentation.
Page 38
3-6 Compaq UPS T2200 XR Operation and Reference Guide Site Wiring Fault Indicator (LED 6) Table 3-2 Site Wiring Fault Indicator – LED 6 Color Meaning No ground connection between utility power and the UPS. The line and neutral connections between utility power and the UPS are reversed.
UPS rear panel. Placing the UPS in Operate Mode The Compaq UPS T2200 XR models may be placed in Operate mode if either of the following conditions apply: The UPS is powered up and in Standby mode (The Utility LED is...
Page 40
3-8 Compaq UPS T2200 XR Operation and Reference Guide Press and hold the ON button (2) until the Utility LED (1) turns solid green, indicating that power is available at the UPS output receptacles. The UPS acknowledges compliance with a short beep.
Operation 3-9 Returning to Standby Mode When the UPS is in Operate mode (the Utility LED is solid green), press and hold the STANDBY button (2) until the audio alarm sounds. This will place the UPS in Standby mode. The Utility LED (1) will flash, and power to the loads will cease.
3-10 Compaq UPS T2200 XR Operation and Reference Guide Initiating a Self-test To initiate a self-test, press and hold the TEST/ALARM RESET button (1) for three seconds. Figure 3-4. TEST/ALARM RESET button (1) IMPORTANT: A portion of the self-test requires battery power; the self-test cannot be initiated if the batteries are less than 90 percent charged.
Operation 3-11 Audio Alarm The UPS may sound an audio alarm to warn the user that an alarm condition exists. IMPORTANT: Certain audio alarms can be disabled. See Chapter 6, “Troubleshooting,” for more information. Silencing an Audio Alarm To silence the alarm, press the TEST/ALARM RESET button (1). Figure 3-5.
Chapter Configuration This chapter contains information on the following topics: Placing the UPS in Configure mode Configuration parameters and the LED indicators Using the front panel LED display and controls to monitor and change configuration parameters...
4-2 Compaq UPS T2200 XR Operation and Reference Guide Placing the UPS in Configure Mode The Compaq UPS T2200 XR can enter the Configure mode while in the Operate or Standby mode. In order to access the configuration controls, the UPS front bezel (1) must be removed by snapping the bezel off.
Page 46
Configuration 4-3 To place the UPS in Configure mode, press and hold the Configure button (5) for three seconds. When the Configure button is released, the front panel configuration parameters (referenced below and further defined in Table 4-1) will flash in unison and the Configure mode ON LED (4) will illuminate solid green. Figure 4-2.
4-4 Compaq UPS T2200 XR Operation and Reference Guide Configuration Parameters and the LED Indicators In the Configure mode, the front panel configuration parameters (referred to as LEDs 6 to 10) are detailed in the following table. Figure 4-3. The front panel configuration parameters and LED indicators Table 4-1 Configuration Parameters/LED Indicators in Configure Mode (LED ;...
Configuration 4-5 Changing Configuration Parameters The Configure mode may be entered from the Operate or Standby mode. Figure 4-4. Configure mode controls and Configuration parameter LED display Configure mode button controls Configuration parameter LED display ON button General Alarm (advances to next configurable option setting) STANDBY button On Battery (accepts flashing voltage configuration;...
Page 49
4-6 Compaq UPS T2200 XR Operation and Reference Guide 3. To advance to the next configuration parameter value (to the right), press the ON button (1). The selected voltage configuration LED will blink until accepted by pressing the STANDBY button (2) and the previously selected configuration parameter LED will turn off.
Chapter Battery Maintenance This chapter contains information on the following topics: Precautions to be observed when maintaining or replacing batteries Charging batteries When to replace batteries Pre-Failure Battery Warranty Obtaining new batteries Replacing batteries Care and storage of batteries...
Remove watches, rings, or other metal objects. Use tools with insulated handles. Charging Batteries The Compaq UPS T2200 XR models automatically charge the batteries when connected to utility power. No user intervention is required while the UPS is in use.
Compaq power management software that the battery may fail, the battery is replaced free of charge under the warranty. Compaq maintains the highest standards in the industry, as evidenced by the Compaq Pre-Failure Battery Warranty. The Pre-Failure Battery Warranty is...
5-4 Compaq UPS T2200 XR Operation and Reference Guide Obtaining New Batteries Compaq supplies spare battery packs for UPS T2200 XR models. Obtain spare batteries for the UPS when the Bad Battery/Low Battery LED illuminates, meaning that new batteries may be required within 30 to 60 days.
Battery Maintenance 5-5 To replace batteries with the UPS in Operate mode (hot-swapping) Batteries may be replaced (hot-swapped) without powering off the UPS if the UPS is not supplying battery power to devices (utility is present, indicating that the UPS is supplying utility power). Step 2: Removing the Battery Pack Follow this procedure to remove the battery pack: 1.
Page 55
5-6 Compaq UPS T2200 XR Operation and Reference Guide 3. Remove the metal battery bracket and set to the side. Figure 5-3. Removing the metal battery bracket 4. The battery pack is surrounded by a plastic cover. Unfasten the plastic handle (1) and partially remove the battery pack (2).
IMPORTANT: The batteries will charge to 90 percent of their capacity within less than 3 hours. Compaq recommends allowing the batteries to charge for 24 hours before using the UPS to supply backup power to devices. The load may not be fully protected for...
5-8 Compaq UPS T2200 XR Operation and Reference Guide Step 5: Disposing of Used Batteries The spare battery kit includes the instructions and packaging required to return used batteries to the appropriate location for disposal. Do not dispose of used batteries with general office or household waste.
Chapter Troubleshooting This chapter provides information on the following topics: Troubleshooting problems that occur during UPS start Troubleshooting problems that occur after start Repairing the UPS...
6-2 Compaq UPS T2200 XR Operation and Reference Guide Troubleshooting During Start If problems occur when starting the Compaq UPS T2200 XR models, select the appropriate symptom for possible causes and actions suggested. Table 6-1 Troubleshooting Guide (UPS Start) Symptom...
Troubleshooting 6-3 Troubleshooting After Start For problems that occur after the UPS has gone through the startup self-test sequence, these suggested actions address possible causes. Table 6-2 Troubleshooting Guide (After Start) Symptom Possible Cause Suggested Action Audio Alarm Alarm condition exists. Identify red LED associated with this alarm condition.
Page 61
6-4 Compaq UPS T2200 XR Operation and Reference Guide Table 6-2 Troubleshooting Guide (After Start) continued Symptom Possible Cause Suggested Action UPS frequently Utility power variations. The utility voltage is frequently switches between outside the UPS operating range. utility and battery Update the configuration.
Compaq service audio alarm representative. cannot be silenced Repairing the UPS Repairs to the UPS must be carried out by Compaq or an authorized Compaq service representative. Other than battery replacement, there are no UPS user-serviceable parts.
Identification Numbers For the purpose of regulatory compliance certifications and identification, Compaq UPS T2200 XR models are assigned a Compaq Series Number. The Compaq Series Numbers for this product are shown below. The UPS T2200 XR Series Number can be found on the Regulatory Compliance label, along with the required approval markings and information.
A-2 Compaq UPS T2200 XR Operation and Reference Guide Federal Communications Commission Notice Part 15 of the Federal Communications Commission (FCC) Rules and Regulations has established Radio Frequency (RF) emission limits to provide an interference-free radio frequency spectrum. Many electronic devices, including computers, generate RF energy incidental to their intended function and are, therefore, covered by these rules.
For questions regarding your product, contact: Compaq Computer Corporation P. O. Box 692000, Mail Stop 530113 Houston, Texas 77269-2000 or call 1-800-652-6672 (1-800-OK COMPAQ) For questions regarding this FCC declaration, contact: Compaq Computer Corporation P. O. Box 692000, Mail Stop 510101 Houston, Texas 77269-2000 or call (281) 514-3333.
A-4 Compaq UPS T2200 XR Operation and Reference Guide Modifications The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Compaq Computer Corporation may void the user's authority to operate the equipment. Cables...
Regulatory Compliance Notices A-5 European Union Notice Products with the CE Marking comply with both the EMC Directive (89/336/EEC) and the Low Voltage Directive (73/23/EEC) issued by the Commission of the European Community. Compliance with these directives implies conformity to the following European Norms (in brackets are the equivalent international standards): EN50091-1 –...
The UPS is provided with a sealed lead-acid battery pack. There is a danger of explosion and risk of personal injury if the battery is incorrectly replaced or mistreated. Replacement is to be done by an authorized Compaq service representative using the Compaq spare designated for this product. For more information about battery replacement or proper disposal, contact your Compaq authorized reseller or your Authorized Service Provider.
Appendix Electrostatic Discharge To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices.
B-2 Compaq UPS T2200 XR Operation and Reference Guide Grounding Methods There are several methods for grounding. Use one or more of the following methods when handling or installing electrostatic-sensitive parts: Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis.
C-2 Compaq UPS T2200 XR Operation and Reference Guide Physical Specifications Table C-1 Physical Specifications – UPS T2200 XR Models Feature U.S. Metric Dimensions Width 8.1 in 206 mm Height 9.7 in 246 mm Depth* 19.1 in 485 mm Weight...
UPS. WARNING: Risk of personal injury from electric shock. The UPS T2200 XR H NA and T2200 XR H INT’L models are not suitable for installation where the total Earth (ground) conductor leakage current for all...
C-4 Compaq UPS T2200 XR Operation and Reference Guide Output Specifications Table C-3 Output Specifications – UPS T2200 XR Models Effective Nominal Power Load UPS Model Output Receptacles Rating (W) Segment # T2200 XR NA 1920 1600 3 x 5-15R...
Page 75
Specifications C-5 Table C-4 Output Specifications – UPS T2200 XR Models Available Available Configuration Nominal Nominal Characteristics Setting (VAC) Output Voltage Output Voltage (VAC) (VAC) on Battery Voltage 110* 220* Source of Power Regulation Output Utility power -10% to +6% of nominal output voltage...
Specifications C-7 Environmental Specifications Table C-6 Environmental Specifications – UPS T2200 XR Models Feature Specification Operating temperature C to 40 C (50 F to 104 UL-tested at 25 C (77 Non-operating temperature C to 55 C (5 F to 131...
Page 78
6-3 care and storage 5-8 silencing 3-3, 3-11 warning to use authorized after utility power restored 3-11 Compaq service requirement to address alarm representative 5-2 condition 3-11 warning to use qualified service personnel ix warnings on risk of fire or...
Page 79
2 Compaq UPS T2200 XR Operation and Reference Guide battery maintenance See care and Compaq Series Numbers A-1 storage of batteries Compaq T2200 XR See Battery Recharge Date label Uninterruptible Power System checking the battery recharge T2200 XR date, illustrated 2-6...
Page 80
1-3 Compaq authorized option cards 1-10 resellers xi rear panel 1-4 Compaq website xi UPS T2200 XR 1-8 technical support telephone warranties 1-11 numbers x Federal Communications hot-swapping batteries See Commission (FCC) notice A-2 replacing batteries cables A-4 http://www.compaq.com xi...
Page 81
4 Compaq UPS T2200 XR Operation and Reference Guide items not supplied with the Load Level LEDs UPS kit 2-2 explained 3-5 items supplied with the UPS troubleshooting alarm kit 2-2 condition 6-4 powering up the UPS 2-8 requirements 2-2...
Page 82
Compaq Power Products hot-swapping 5-7 Software Reference testing new batteries 5-7 Guide 2-2 with the UPS in Operate Compaq UPS T2200 XR mode 5-5 Operation and Reference with the UPS off 5-4 Guide 2-2 problems See troubleshooting...
Page 83
6 Compaq UPS T2200 XR Operation and Reference Guide storage See care and storage of batteries safety information ix switching the UPS to Standby See safety precautions STANDBY button battery handling ix symbols in text viii high Earth conductor leakage...
Page 84
2-9 $25,000 Computer Load troubleshooting alarm Protection Guarantee 1-11 conditions 6-3 applicability 1-11 limited warranty 1-11 pre-failure battery 1-11, 5-3 three-year limited 1-11 VCCI Notice for Japan A-5 weight symbol ix voltage level www.compaq.com x configuring nominal 4-4...