INSTALLATION OF THE INVERTER

AND INSTRUCTIONS
Installation of the inverter
Note - Some inverter models may be installed outside an enclosure. See Appendix 2 for details.
Installation on the enclosure
FR-A720-00900 or less
FR-A740-00440 or less
FR-A760-00330 or less
REMARKS
To use an enclosed brake resistor for the FR-A760-00061 or less, refer to page 8.
General Precaution
The bus capacitor discharge time is 10 minutes. Before starting wiring or inspection, switch power off, wait for more
than 10 minutes, and check for residual voltage between terminal P/+ and N/- with a meter etc., to avoid a hazard
of electrical shock.
Environment
Before installation, check that the environment meets following specifications.
FR-A720/A740
LD, ND (initial setting),HD:
-10°C to + 50°C (14°F to 122°F) (non-freezing)
SLD: -10°C to + 40°C (14°F to 104°F) (non-freezing)
FR-A760
LD, ND (initial setting):
Surrounding air
-10°C to +40°C (14°F to 104°F) (non-freezing) (00840 or less)
temperature
-10°C to +50°C (14°F to 122°F) (non-freezing) (01040 or more)
HD:
-10°C to + 40°C (14°F to 104°F) (non-freezing)
SLD:
-10°C to +30°C (14°F to 86°F) (non-freezing) (00061 or less)
-10°C to +40°C (14°F to 104°F) (non-freezing) (00120 or more)
Ambient humidity
90%RH or less (non-condensing)
Storage temperature
-20°C to +65°C (-4°F to 149°F)
Ambience
Indoors (No corrosive and flammable gases, oil mist, dust and dirt.)
Maximum 1000m (3280.80feet) above sea level for standard operation. After that derate by 3% for
every extra 500m (1640.40feet) up to 2500m (8202feet) (91%).
Altitude, vibration
5.9m/s
2
*1
2.9m/s
or less for the FR-A740-03250 (FR-A760-02210) or more
CAUTION
• Install the inverter on a strong surface securely and vertically with bolts.
• Leave enough clearances and take cooling measures.
• Avoid places where the inverter is subjected to direct sunlight, high temperature and high humidity.
• Install the inverter on a non-combustible wall surface.
2
FR-A720-01150 or more
FR-A740-00570 or more
FR-A760-00550 or more
Fix six positions for the FR-A740-03250 to
06830 (FR-A760-02210 to 06630) and fix
eight positions for the FR-A740-07700 to
09620.
2
or less at 10 to 55Hz (directions of X, Y, Z axes)
CAUTION
• When encasing multiple inverters, install them in
parallel as a cooling measure.
• Install the inverter vertically.
10cm(3.94inches)
or more
*2
10cm(3.94inches)
or more
*2
*1 1cm or more for FR-A720-00175
(FR-A740-00090, FR-A760-00061) or less
10cm or more for FR-A720-02880
(FR-A740-01440, FR-A760-01040) or more
*2 20cm or more for FR-A720-02880
(FR-A740-01440, FR-A760-01040) or more
5cm
(1.97inches)
Measurement
position
*1
Vertical
Measurement
position
Inverter
5cm
(1.97inches)
5cm
(1.97inches)