FR-A760-03040 to 06630-NA
R1/L11 S1/L21
R/L1 S/L2 T/L3 N/-
Power supply
DC reactor
CAUTION
· The power supply cables must be connected to R/L1, S/L2, T/L3. (Phase sequence needs not to be matched.) Never connect
the power cable to the U, V, W of the inverter. Doing so will damage the inverter.
· Connect the motor to U, V, W. At this time, turning on the forward rotation switch (signal) rotates the motor in the
counterclockwise direction when viewed from the motor shaft.
· When wiring the inverter main circuit conductor of the FR-A740-04320 (FR-A760-03040) or more, tighten a nut from the right
side of the conductor. When wiring two wires, place wires on both sides of the conductor. (Refer to the drawing below.) For
wiring, use bolts (nuts) provided with the inverter.
Screw size (M4)
Charge lamp
Jumper
Screw size (M12)
P/+
P/+
IM
Motor
Screw size (M10)
WIRING