3.2 Terminal connection diagram (FR-A760)
Sink logic
*1. DC reactor
Be sure to connect the DC reactor
Main circuit terminal
supplied with the FR-A760-01040 or more.
When using the FR-A760-00840 with LD
Control circuit terminal
or SLD set, always use a DC reactor
(option).
When a DC reactor is connected to the
FR-A760-00840 or less, remove the
jumper across P1-P/+.
Three-phase AC
power supply
*2. To supply power to the
control circuit separately,
remove the jumper across
R1/L11 and S1/L21.
Control input signals (No voltage input allowed)
Terminal functions vary with
the input terminal
assignment (Pr. 178 to Pr. 189)
(Refer to the Instruction
Manual)
holding selection
Multi-speed
selection
*3. JOG terminal can be used
as pulse train input terminal.
Use Pr. 291 to select
JOG/pulse.
Second function selection
*4. AU terminal can be
used as PTC input
terminal.
Terminal 4 input selection
(Current input selection)
Selection of automatic restart
after instantaneous
Contact input common
(Common for external power supply transistor)
Frequency setting signal (Analog)
Frequency setting
potentiometer
1/2W1k Ω
*6
* 5. Terminal input specifications
can be changed by analog
input specifications
Auxiliary
switchover (Pr. 73, Pr. 267).
Set the voltage/current input
switch in the OFF position to
Terminal
select voltage input (0 to 5V/0
to10V) and ON to select
(Current
current input (4 to 20mA).
(Refer to the Instruction
Manual)
*6 . It is recommended to use 2W1kΩ
when the frequency setting signal
is changed frequently.
CAUTION
·
To prevent a malfunction due to noise, keep the signal cables more than 10cm (3.94inches) away from the power cables. Also separate the main
circuit wire of the input side and the output side.
·
After wiring, wire offcuts must not be left in the inverter.
Wire offcuts can cause an alarm, failure or malfunction. Always keep the inverter clean.
When drilling mounting holes in an enclosure etc., take care not to allow chips and other foreign matter to enter the inverter.
·
Set the voltage/current input switch correctly. Different setting may cause a fault, failure or malfunction.
Earth
(Ground)
MCCB
MC
R/L1
S/L2
T/L3
R1/L11
Jumper
S1/L21
*2
Earth
(Ground)
Forward
rotation
start
Reverse
rotation
start
Start self-
High speed
Middle
speed
Low speed
Jog mode
MRS
Output stop
Reset
power failure
24VDC power supply
10E(+10V)
10(+5V)
3
2
1
(+)
1
input
(-)
(+)
4 input
(-)
input)
Connector
for plug-in option
connection
Brake unit
*1
(Option)
R
*7
Jumper
Jumper
P1
P/+
PX
PR

Main circuit

Control circuit

STF
STR
STOP
RH
RM
RL
JOG
*3
RT
RES
*4
AU
AU
PTC
CS
SD
PC
PU
connector
*5
Voltage/current
input switch
4 2
ON
USB
OFF
connector
0 to 5VDC
(Initial value)
2
0 to 10VDC
selected
*5
0 to 20mADC
5
(Analog common)
0 to ± 10VDC
(Initial value)
selected
0 to ± 5VDC
*5
4 to 20mADC
(Initial value)
4
0 to 5VDC
*5
selected
0 to 10VDC
Option connector 1
Option connector 2
Option connector 3
Terminating
resistor
*7. Brake resistor (Accessories)
The brake resistor is provided with the FR-
A760-00017 to 00061. Connect the accessory
brake resistor to P/+-PR.
Terminal PR is provided for the FR-A760-00017
to 00330.
Install a thermal relay to prevent an overheat
N/-
and burnout of the brake resistor.
(Refer to the Instruction Manual)
U
V
W
C1
Terminal functions
B1
Relay output 1
vary with the output
(Alarm output)
terminal assignment
A1
(Pr. 195, Pr. 196)
(Refer to the
Instruction Manual)
C2
B2
Relay output 2
A2
Open collector output
RUN
Running
Terminal functions
SU
vary with the output
Up to frequency
terminal assignment
IPF
(Pr. 190 to Pr. 194)
Instantaneous
power failure
(Refer to the
OL
Instruction Manual)
Overload
FU
Frequency detection
SE
Open collector output common
Sink / source common
* 8. It is not necessary
*9. FM terminal can be
when calibrating the
indicator from the
operation panel.
-
+
FM
(Frequency meter, etc.)
*9
Calibration
resistor * 8
SD
AM
(+)
Analog signal output
5
(-) (0 to 10VDC)
RS-485 terminals
TXD+
Data transmission
TXD-
RXD+
Data reception
RXD-
SG
GND
VCC
(Permissible load
5V
current 100mA)
WIRING
Motor
IM
Earth (Ground)
Relay output
used for pulse train
output of open collector
output using Pr. 291.
Indicator
Moving-coil type
1mA full-scale
7