PARAMETER LIST
Parameter
Name
Energy saving control
60
selection
61
Reference current
Reference value at
62
acceleration
Reference value at
63
deceleration
Starting frequency for
64
elevator mode
65
Retry selection
Stall prevention operation
66
reduction starting frequency
Number of retries at fault
67
occurrence
68
Retry waiting time
69
Retry count display erase
Special regenerative brake
70
duty
71
Applied motor
72
PWM frequency selection
73
Analog input selection
74
Input filter time constant
Reset selection/
75
disconnected PU detection/
PU stop selection
76
Fault code output selection
77
Parameter write selection
Reverse rotation prevention
78
selection
79
Operation mode selection
80
Motor capacity
81
Number of motor poles
82
Motor excitation current
83
Rated motor voltage
84
Rated motor frequency
Speed control gain (Advanced
89
magnetic flux vector)
90
Motor constant (R1)
91
Motor constant (R2)
26
Setting
Initial
Parameter
Range
Value
0
0, 4
0 to 500A,
9999/
9999
0 to 3600A,
9999
*2
0 to 220%,
9999
9999
0 to 220%,
9999
9999
0 to 10Hz,
9999
9999
0
0 to 5
0 to 400Hz
60
Hz
0 to 10,
0
101 to 110
1s
0 to 10s
0
0
0 to 30%/
0%
0 to 10%
*2
0 to 8, 13 to
18, 20, 23, 24,
30, 33, 34, 40,
43, 44, 50, 53,
0
54
/0 to 8, 13 to
18, 30, 33, 34
*5
0 to 15/
2
0 to 6, 25
*2
1
0 to 7, 10 to 17
0 to 8
1
0 to 3, 14 to
17, 100 to 103,
14
114 to 117
0
0, 1, 2
0, 1, 2
0
0, 1, 2
0
0, 1, 2, 3, 4, 6,
0
7
0.4 to 55kW,
9999/
9999
0 to 3600kW,
9999
*2
2, 4, 6, 8, 10,
12, 14, 16, 18,
9999
20, 9999
0 to 500A,
9999/
9999
0 to 3600A,
9999
*2
200/400/
0 to 1000V
575V
*6
10 to 120Hz
60
Hz
0 to 200%,
9999
9999
Ω
0 to 50
,
9999/
9999
0 to 400mΩ,
9999
*2
Ω
0 to 50
,
9999/
9999
0 to 400mΩ,
9999
*2
Name
92
Motor constant (L1)
93
Motor constant (L2)
94
Motor constant (X)
95
Online auto tuning selection
96
Auto tuning setting/status
100
V/F1(first frequency)
101
V/F1(first frequency voltage)
102
V/F2(second frequency)
V/F2(second frequency
103
voltage)
104
V/F3(third frequency)
V/F3(third frequency
105
voltage)
106
V/F4(fourth frequency)
V/F4(fourth frequency
107
voltage)
108
V/F5(fifth frequency)
109
V/F5(fifth frequency voltage)
Third acceleration/
110
deceleration time
111
Third deceleration time
112
Third torque boost
113
Third V/F (base frequency)
Third stall prevention
114
operation current
Third stall prevention
115
operation frequency
Third output frequency
116
detection
PU communication station
117
number
118
PU communication speed
PU communication stop bit
119
length
PU communication parity
120
check
Number of PU
121
communication retries
PU communication check
122
time interval
PU communication waiting
123
time setting
PU communication CR/LF
124
selection
Terminal 2 frequency setting
125
gain frequency
Terminal 4 frequency setting
126
gain frequency
Setting
Initial
Range
Value
Ω
0 to 50
(0 to 1000mH), 9999/
9999
0 to 3600mΩ
(0 to 400mH), 9999
*2
Ω
0 to 50
(0 to 1000mH), 9999/
9999
0 to 3600mΩ
(0 to 400mH), 9999
*2
Ω
0 to 500
(0 to 100%), 9999/
9999
0 to 100Ω
(0 to 100%), 9999
*2
0
0 to 2
0
0, 1, 101
0 to 400Hz,
9999
9999
0 to 1,000V
0V
0 to 400Hz,
9999
9999
0V
0 to 1,000V
0 to 400Hz,
9999
9999
0V
0 to 1,000V
0 to 400Hz,
9999
9999
0 to 1,000V
0V
0 to 400Hz,
9999
9999
0V
0 to 1,000V
0 to 3600/
9999
360s, 9999
0 to 3600/
9999
360s, 9999
9999
0 to 30%, 9999
0 to 400Hz,
9999
9999
150%
0 to 220%
0
0 to 400Hz
0 to 400Hz
60Hz
0
0 to 31
48, 96, 192,
192
384
0, 1, 10, 11
1
2
0, 1, 2
1
0 to 10, 9999
0, 0.1 to
9999
999.8s, 9999
0 to 150ms,
9999
9999
1
0, 1, 2
0 to 400Hz
60
Hz
Hz
0 to 400Hz
60