Panasonic FP7 User Manual page 41

Cpu unit. com port communication
Hide thumbs Also See for FP7:
Table of Contents

Advertisement

 Output signal
Output
Communication
signal
port
Y0
For COM.1 Port
Y1
For COM.2 Port
Y2
For COM.0 Port
Y3
-
- Y7
Y8
For COM.1 Port
Y9
For COM.2 Port
YA
For COM.0 Port
YB
-
YC
For COM.1 Port
YD
For COM.2 Port
YE
For COM.0 Port
YF
-
Y10
For COM.1 Port
Y11
For COM.2 Port
Y12
For COM.0 Port
Y13
-
Y14
For COM.1 Port
Y15 -
-
Y1F
(Note 1) When transmission is completed within one scan, it turns off when the GPSEND command is executed in the
subsequent scan.
NOTE
Each contact in the table above is used for reading the operation status. Do
not write over it with a user program. (excluding Y10 - Y12 and Y14)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
3.2 Input/Output Signals Used for Communication
Name
Reports the result of sending in master
communication or general-purpose
Sending done
communication.
result
Normal completion: 0, Abnormal completion: 1
Undefined
Do not turn on "undefined". (Default setting is 0.)
It turns on (1) during sending in the general-
Sending general-
purpose communication mode.
purpose
(Note 1)
communication
flag
Sending done: 0, Sending: 1
Undefined
Do not turn on "undefined". (Default setting is 0.)
It turns on (1) during sending in the master
Sending master
communication mode.
communication
flag
Sending done: 0, Sending: 1
Undefined
Do not turn on "undefined". (Default setting is 0.)
By turning on (1) Y10 - Y12, the communication
channel can be reset.
Without a request to reset = 0, With a request to
reset = 1
After ON (1) is output and the completion of the
reset is confirmed by X10 - X12, return to OFF
(0). The reset is performed only once when this
Request to reset
signal rises.
CH
This function can be used to delete
unnecessary received data or to clear errors
before starting normal reception.
1: Sending canceled
2: Reception canceled
3: Re-set communication parameters
4: Clear error information (only for errors that
can be cleared)
Undefined
Do not turn on "undefined". (Default setting is 0.)
By turning on (1) this output, RTS is controlled.
Transmission from the communication partner is
permitted = 0
Output
Transmission from the communication partner is
RTS signal
prohibited=1
Monitor the CTS signal from the communication
partner with X14.
Undefined
Do not turn on "undefined". (Default setting is 0.) -
Description
Valid
communication
mode
MEWTOCOL
MODBUS-RTU
General-purpose
communication
General-purpose
communication
MEWTOCOL
MODBUS-RTU
General-purpose
communication
When RS/CS is
set to valid in
Communication
Cassette COM1
3-5

Advertisement

Table of Contents
loading

Table of Contents